background image

ENGLISH – Tiki medical

 47

30°

30°

Summary of Contents for 1200-51

Page 1: ...www tikisafety com P N 1091 01 EN ENGLISH MANUAL ...

Page 2: ...e manual on hand for reference Tiki Safety AB performed every effort to produce the Tiki medical mask to superior industrial standards legal requirements safety and comfort of the user If you as a user are pleased with the Tiki medical mask tell your network If you are despite our effort either not fully pleased or presume our Tiki medical mask holds points of improvement please tell us And give u...

Page 3: ...2 1 1 General description 12 2 1 2 Parts 12 2 1 3 Pressure sensor 14 2 2 Buttons and indicator lights 15 2 2 1 The on off button 15 2 2 2 The lights 15 2 2 3 The button for the lights 15 2 2 4 Three 3 red indicator lights 16 2 3 Indications of the red indicator lights 16 2 3 1 Blower off 16 2 3 2 Blower on 16 2 3 3 Low battery power 16 2 3 4 Filter warning or leak 17 2 4 Specifications 18 2 4 1 Di...

Page 4: ... 6 Testing the mask during use 32 4 7 Take the Tiki medical mask off 33 5 Maintenance procedures 34 5 1 Cleaning the Tiki medical mask 35 5 2 Replace the inhalation filter white 36 5 3 Replace the exhalation filter green 37 5 4 Storage 38 6 Disposal 39 7 Standards 40 7 1 Reports 40 7 1 1 Notified body 40 7 1 2 External body 40 7 1 3 Performance test 40 7 2 Protection class 40 7 3 Regulation standa...

Page 5: ...to read it through thoroughly In the video on www tikisafety com video Furthermore Tiki Safety AB applied dedicated attention on the safe and ergonomic use of the Tiki medical mask towards safe and easy use First read this user manual and watch the indicated videos If after those the user is still not sure about some aspects of the safety aspects preparation use and maintenance of the Tiki medical...

Page 6: ... mask touches the face 1 3 2 Protruding nose A protruding nose might touch the inner edge of the Tiki medical mask and cause either Discomfort to the nose of the user Or the risk that gaps occur between the Tiki medical mask and the face of the user Tiki Safety AB designed the Tiki medical mask to industrial standards on ergonomics yet a situation as a protruding nose can occur To prevent the indi...

Page 7: ...he Tiki medical mask to the risks of these hazardous mixtures To train the users of the Tiki medical mask to the risks of hazardous mixtures is under the responsibility of either the user or the organisation that holds responsibility over the user as for example the employer of the user Tiki Safety AB recommends that the user receives training on the risks and preventive and protective measures to...

Page 8: ...asic components The Tiki medical mask holds the basic components as described in paragraph 2 1 Description on page 12 These basic components are manufactured in the materials as indicated below None of these materials expose the user of the Tiki medical mask to a health or a safety issue 1 7 2 Batteries The blower with the internal battery and the external battery contain both lithium polymer LiPo...

Page 9: ... before use on page 23 4 Use procedures on page 27 5 Maintenance procedures on page 34 The video on www tikisafety com video The risk that hazardous mixtures enter the enclosed air volume between the Tiki medical mask and the face of the user depends on the verification of the user that the seal is tight As extra measure to reduce this risk Tiki Safety AB designed the Tiki medical mask as a mask w...

Page 10: ...less than 19 5 As the Tiki medical mask is equipped with a battery the functionality of the Tiki medical mask depends on the battery time It is under the responsibility of the user to monitor the energy level of the battery before use and monitor that energy level at use at all times If the energy level of the battery level is too low a risk situation occurs The following situations mark that eith...

Page 11: ...uch instructions In a safe environment and as adhered to the instructions to transit take the Tiki medical mask off as to the procedure 4 7 Take the Tiki medical mask off on page 33 Clean the Tiki medical mask after use therefore refer to The MSDS of the hazardous mixture The procedure 5 1 Cleaning the Tiki medical mask on page 35 If the hazardous mixture is of such nature that either the inhalati...

Page 12: ...al mask can for example be used in a medical environment were patients hold a suppressed immunity system due to sickness or other reason This to prevent that such patients are infected involuntary with aerosol or droplet pathogens of the medical personnel 2 1 2 Parts Aside the below indicated the Tiki medical mask is shipped with the following items that are not indicated on figure 1 This user man...

Page 13: ...rticle filter Mark that the Tiki medical mask includes only particle filters and is therefore not be used in areas that contain gaseous solvents and other hazardous airborne contagions that a P3 particle filter does not remove The exhalation particle filter is composed of ABS plastics and HEPA fibreglass media The battery charger supplies electric power to the internal battery of the blower and th...

Page 14: ...e 1c The blower with internal battery 1d The harness 1e The battery charger 1f The car charger optional 1g The external battery pack with cable optional 1h The exhalation filter green 1i The screw seal 2 1 3 Pressure sensor The blower of the Tiki medical mask contains a pressure sensor This pressure sensor detects through the little hole on top of the visor the pressure in the mask ...

Page 15: ...dicator lights The buttons can be used as the blower is positioned in the mask Refer to figure 11 11a The on off button 11b The lights to apply extra light at the work spot 11c The button for the lights at 11b 11d Three 3 indicator lights 2 2 1 The on off button Use the on off button to Calibrate the blower unit according to 4 4 Calibrate the blower on page 31 Start and stop the blower unit To do ...

Page 16: ...lashes and thus emits light on and off 2 3 Indications of the red indicator lights 2 3 1 Blower off None of the indicator lights are on this indicates that the blower is off If after attempts to start the blower the indicator lights do not emit light and the sound of the blower can not be heard charge the battery 2 3 2 Blower on The indicator light that is closest to the on off button is on This i...

Page 17: ...s an alarm sound every one 1 second This indicates that either The inhalation filter is blocked A major leak occurred In either situation the user has to Leave the hazardous environment Evaluate what caused either the leak or the situation with the filter If a situation with the inhalation filter occurred replace the filter as to 5 2 Replace the inhalation filter on page 36 If a leak occurred due ...

Page 18: ... size medium 440 g In size large 450 g Note that the design of the Tiki medical mask has a ergonomic shape with contact around the entire face and a harness that tightens the mask at the back of the head This design distributes the weight over the entire head and leads to efficient and ergonomic comfort Item Specifications Battery warning time 15 min normal conditions Minimum free flow air 200 l m...

Page 19: ...to the enclosed air volume between the Tiki medical mask and the face of the user for a pre set time The test measures whether the mask can hold the vacuum for the pre set time Only masks that hold the vacuum for the pre set time are validated and further processed in the production Masks that do not hold the vacuum for the pre set time are not validated and not further processed in the production...

Page 20: ...ted Indication that a battery is present Warning symbol on the fact that the Li ion battery is to be recycled separate Warning symbol on the fact that the respective part is to be disposed to a dedicated waste disposal process Hourglass next to the hourglass are the month and the year indicated the expiry date of the part Note this is the storage time for an un opened package Also refer to paragra...

Page 21: ... air to the user The exhalation filter green filters the user s exhaled air from hazardous mixtures and pathogens that the user carries The constituent materials of the Tiki medical mask are indicated at sub paragraph 1 7 1 Basic components on page 8 These constituent materials are specifically chosen designed so and incorporated so as to ensure appropriate user respiration and respiratory hygiene...

Page 22: ...ws prolonged daily use or and failing this limited leak tightness necessitating a restriction of the period of wear 2 7 Not intended use The Tiki medical mask is under no conditions to be used as either a breathing apparatus to dive a snorkel or a device for underwater exploration The Tiki medical mask is not intended to Protect the user in liquids Aid as a device to add buoyancy to the user Be us...

Page 23: ...topic based procedure The paragraphs and thus the topic based procedures are deliberately positioned on one 1 page per one 1 procedure This lay out is intended to enable that the end user can produce quick reference cards for distribution in their internal organisation Note that at every time every procedure is a part of this user manual as an integral part of it ...

Page 24: ...urs in the enclosed air volume between the mask and the face of the user This is good and proves the seal is OK b The user can breathe in and a vacuum does not occur in the enclosed air volume between the mask and the face of the user This is not good and proves the seal is not OK 7 In case the situation 6a occurred take off the mask and remove the paper 8 In case the situation 6b occurred evaluat...

Page 25: ...nd while holding it osition the inhalation filter in a 30 angle to the blower as to figure 6 Observe the direction to the face as indicated with the text and arrows This side to the face 6 Turn the inhalation filter white from the 30 to a 0 angle to attach the inhalation filter white to the blower as to figure 7a 30 7 Position the exhalation filter green in a 30 angle to the axes of the mask as to...

Page 26: ... for part number b The next six 6 numbers and hyphen indicate the part number c D stands for date d The next four 4 numbers indicate the year with two 2 numbers and month of production with two 2 numbers e B stands for batch f The next two 2 numbers indicate the batch in which the part is manufactured 5 Use the six 6 number and hyphen between PN and D to order parts as to the procedure 5 3 Replace...

Page 27: ...tribution in their internal organisation Mark that at every time every procedure is a part of this user manual as an integral part of it Warning biohazard In the procedures of the chapters 4 Use procedures and 5 Maintenance procedures ensure not to contaminate the user to the hazardous mixtures on the outside of the mask Note it is under the responsibility of either the user or the organisation th...

Page 28: ...s optional and is to be ordered separately 3 Connect the battery charger 1e on figure 1 to the batteries 4 If the indicator light on the battery charger is red the battery is charging 5 If the indicator light on the battery charger is green the battery is fully charged refer to figure 2 6 If only the internal battery is used the Tiki medical mask is ready for use as the internal battery is charged...

Page 29: ...ser b Remove the screw seal or red tape on the top left of the mask c Insert and screw the cable of the external battery to the internal battery making sure to observe that the pin configuration s meet refer to figures 3 and 8 d Connect the cable to the external battery 5 Use the Tiki medical mask as to the below procedures 6 After use unscrew the cable from the internal battery refer to figure 3 ...

Page 30: ...at 5 4 on page 38 or dispose the mask as to 6 Disposal on page 39 5 Obey the safety indications in chapter 1 and specific to paragraph 1 3 Before use on page 5 6 As necessary tighten long hair in a hair knot 7 Loosen the straps of the harness a bit 8 With one hand hold the outer front of the mask refer to figure 9 9 With the other hand hold the inner part of the harness refer to figure 9 10 Pull w...

Page 31: ...as to the procedure 4 6 Testing the mask during use on page 32 4 5 Adjusting the blower unit speed 1 Press and hold the on off button for three seconds to start the blower unit The blower unit will then start in an automatic speed regulated by the breathing 2 Press the on off button one additional time to change the speed from automatic speed to low speed 3 Press the on off button one additional t...

Page 32: ...he mask is tight to the face and calibrated test the warning system by performing the following a With one hand pull the mask forward as indicated on figure 12 Do this to create a leak b Verify that the alarm is activated as to sub paragraph 2 3 4 Filter warning or leak on page 17 c If the alarm was not activated verify that the batteries are fully charged and try calibrating again d If the alarm ...

Page 33: ... outer front of the mask refer to figure 9 3 With the other hand hold the inner part of the harness refer to figure 9 4 Pull with both hands the mask to its widest stretch 5 Bring with both hands the mask to a position above the head of the user 6 Clean the mask as to the procedure 5 1 Cleaning the Tiki medical mask on page 35 ...

Page 34: ... distribution in their internal organisation Mark that at every time every procedure is a part of this user manual as an integral part of it Warning biohazard In the procedures of the chapters 4 Use procedures and 5 Maintenance procedures ensure not to contaminate the user to the hazardous mixtures on the outside of the mask Note it is under the responsibility of either the user or the organisatio...

Page 35: ...f the manufacturer of the disinfectant agent in regard to temperature time other treatment etc 4 To clean the mask use a paper towel or brush to clean the mixture of water and mild detergent Do not use any solvents 5 Immerse the mask in a water bath with detergent 6 Rinse the mask under warm running water 7 Either use the cloth to dry the mask or leave the mask to dry in open air 8 To the procedur...

Page 36: ...lation filter white 4 Turn the inhalation filter white to a 30 angle as to the blower refer to figure 7b 5 Lift the inhalation filter white from the blower and either a Or if the inhalation white filter is contaminated with biological agents and or hazardous substances treat the inhalation filter to the procedures of either the user or the organisation that holds responsibility over the user b Or ...

Page 37: ...f the leak can not be determined to a mechanical breech and hence the exhalation filter green is clogged perform the below procedure to replace the exhalation filter green 5 Turn the exhalation filter green to a 30 angle as to the axes of the mask refer to figure 7b 6 Pull the exhalation filter from the Tiki medical mask and either c Or if the exhalation filter green is contaminated with biologica...

Page 38: ...e Humidity RH of under 60 Note The Tiki Blower External Battery contain LiPo cells and like all LiPO batteries they must be maintenance charged a minimum once every six 6 months Warning Always supervise all battery charging and stop immediately should the battery swell get hot or if it produces smoke or flames Medium term storage for one 1 to six 6 months at 0 C to 38 C at a RH of under 60 Short t...

Page 39: ...without the blower and the filters is mainly composed of PET and TPE materials and is to be recycled in accordance to local ordinances The moment that such disposal is to be done is to be determined in accordance to either Or regular periodic scheduled system check of the mask Or a scheduled at a determined period of use every X uses every X weeks etc The P3 particle filters are composed of ABS pl...

Page 40: ...ons inspections and examinations on these tests that are carried out are available as to the specifications of EU 2016 425 on request to Tiki Safety AB refer to www tikisafety com 7 1 2 External body The Research Institutes of SwEden RISE performed tests on the Tiki respiratory mask towards the ability and efficiency to clean the Tiki respiratory mask and effectively remove the biohazardous partic...

Page 41: ...pment PPE Mark that regulation EU 2016 425 on PPE replaces the previous directive 89 686 EEC Annex III of the PPE regulation 2016 425 Annex II of the PPE regulation 2016 425 ISO 13688 2013 EN 12942 1998 A2 2008 As the Tiki medical mask applies fully to the above regulation standards there are no other harmonised standards or descriptions of other technical specifications that have been applied in ...

Page 42: ...42 Tiki medical ENGLISH 7 6 Declaration of conformity ...

Page 43: ...n Tiki Safety AB may elect to refund the purchase price in exchange for the return of the product The standard warranty period is 1 year or 2000 work hours from original date of purchase from Tiki Safety AB or authorised reseller This excludes consumables like the filter and the visor of the mask The warranty period may vary depending on local law where the product was originally purchased The war...

Page 44: ...IGATION OR LIABILITY IN CONNECTION WITH THIS PRODUCT TIKI SAFETY AB SHALL NOT BE LIABLE TO PURCHASER OR ANY OTHER PERSON FOR ANY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY Copyright Notice and Disclaimer Tiki Safety AB makes no representations or warranties with resp...

Page 45: ...s EXW this means that Tiki Safety AB makes the ordered products available at their facility and the buyer can trust on the services of their preferred logistics partner and thus take the transport costs Product name Part number Tiki Medical Starter pack small mask 1200 51 Tiki Medical Starter pack medium mask 1200 52 Tiki Medical Starter pack large mask 1200 53 Tiki Medical Mask 5 pack small 1210 ...

Page 46: ...46 Tiki medical ENGLISH ...

Page 47: ...ENGLISH Tiki medical 47 30 30 ...

Page 48: ...m Sales related questions sales tikisafety com Convinced order tikisafety com 46 8 35 32 49 Tiki Safety AB Skällstavägen 9 SE 197 40 Bro Sweden www tikisafety com The Tiki medical mask is designed and manufactured in Sweden English Manual ...

Reviews: