7.2.3.1
Biodegradable hydraulic oil (Optional)
At the request of the customer, the machines can be supplied with biodegradable hydraulic oil compatible with the environment.
Biodegradable hydraulic oil is completely synthetic, without zinc, non-polluting and highly efficient with saturated ester base,
combined with special additives. The machines with biodegradable oil use the same component parts as standard machines, but
the use of such type of oil is best taken into account from machine construction.
In case of wanting to change from mineral-oil based hydraulic oil to “bio” oil, the following procedure must be followed.
7.2.3.2
Emptying
Empty the hot hydraulic oil for entire system operation (oil tank, cylinders, large-volume pipes).
7.2.3.3
Filters
Change the filtering inserts. Use standard filters as indicated by the manufacturer.
7.2.3.4
Washing
After completely emptying the machine, fill with a nominal quantity of “bio” hydraulic oil.
Start the machine and perform all work movements at low revs for at least 30 minutes.
Empty the liquid inside the systems as indicated at 7.2.3.1.1.
Warning:
During the entire washing procedure, avoid air entering the system.
7.2.3.5
Filling
After washing, fill the hydraulic circuit, bleed and check the level.
Bear in mind that contact of fluid with the hydraulic pipes can cause swelling.
Also remember that contact of fluid with the skin can cause reddening or irritation.
Also use suitable PPE during these operations (e.g., protective eyewear and gloves).
7.2.3.6
Commissioning / check
“Bio” oil behaves regularly, but it must be checked by taking a sample at set intervals according to the indications provided below:
CHECK FREQUENCY
NORMAL DUTY
HEAVY DUTY
1
st
CHECK AFTER
50 OPERATING HOURS
50 OPERATING HOURS
2
nd
CHECK AFTER
500 OPERATING HOURS
250 OPERATING HOURS
3
rd
CHECK AFTER
1000 OPERATING HOURS
500 OPERATING HOURS
FOLLOWING CHECKS
1000 HOURS OR 1 OPERATION
YEAR
500 HOURS OR 1 OPERATION
YEAR
The fluid state is therefore constantly monitored, thus allowing its use until its features decay. Normally, in the absence of
contaminating agents, the oil is never completely changed, but only occasionally topped-up.
The oil samples (at least 500ml) must be taken with the system at operating temperature.
It is recommended to use new and clean containers.
The samples must be sent to the “bio” oil supplier.
For more dispatch details, contact Your nearest distributor.
Summary of Contents for AIRO R Series
Page 16: ...Use and Maintenance Manual R13 R17 Series Page 16 Fig 3...
Page 21: ...Use and Maintenance Manual R13 R17 Series Page 21 Fig 4...
Page 81: ...Use and Maintenance Manual R13 R17 Series Page 81...
Page 98: ...Use and Maintenance Manual R13 R17 Series Page 98...
Page 99: ...Use and Maintenance Manual R13 R17 Series Page 99 12 WIRING DIAGRAM 043 08 001...
Page 100: ...Use and Maintenance Manual R13 R17 Series Page 100 043 08 002...
Page 101: ...Use and Maintenance Manual R13 R17 Series Page 101...
Page 103: ...Use and Maintenance Manual R13 R17 Series Page 103 059 08 005 CA1...
Page 104: ...Use and Maintenance Manual R13 R17 Series Page 104 059 08 007 CR...
Page 105: ...Use and Maintenance Manual R13 R17 Series Page 105 059 08 001...
Page 106: ...Use and Maintenance Manual R13 R17 Series Page 106 059 08 006...
Page 107: ...Use and Maintenance Manual R13 R17 Series Page 107...
Page 108: ...Use and Maintenance Manual R13 R17 Series Page 108 043 08 017...
Page 109: ...Use and Maintenance Manual R13 R17 Series Page 109 059 08 012...