A) ON-OFF key and control panel selector (ground/platform)
B) Emergency STOP button
C) Electric or thermic power selector (OPTIONAL)
D) Heat motor starting switch
E) User interface display
G) Powered-on machine warning light
H) Alternator warning light (Diesel models only)
L) Oil warning light (Diesel models only)
M Air filter warning light (Diesel models only)
N) Motor head temperature warning light (Diesel models only)
O) FIRST BOOM LIFTING/LOWERING lever
P) SECOND BOOM LIFTING/LOWERING lever
Q) JIB LIFTING/LOWERING lever
R) TELESCOPIC BOOM OUT/IN lever
S) TURRET ORIENTATION lever
T) PLATFORM ROTATION lever
U) PLATFORM LEVEL compensation lever
The ground controls for operating the structure, except for Jib lifting/lowering, are active only if machine is
levelled and resting on outriggers.
The Jib lifting/lowering control from the ground is always active to enable Jib lifting before loading/unloading
operations of the machine by means of ramps.
5.2.1.
On-off key / control panel selector (A)
The on-off key located on the ground control panel is used to:
turn ON the machine by selecting one of the two control panels:
o
Platform controls enabled with locking key switch set to “platform” symbol. Stable key position with possibility to
extract the key.
o
Ground control panel enabled (for emergency operations) with locking key switch set to "turret" symbol. Position
with action to be kept. When the key is released the machine is turned off.
Turn OFF the control circuits by turning it to OFF.
5.2.2.
Emergency stop button (B)
By pressing this button the machine (as well as the heat motor) is completely stopped; by rotating it of 1/4 turn (clockwise) the
machine can be turned ON by means of the ON-OFF key.
5.2.3.
Thermic or electric work power selector (C) (OPTIONAL)
Holding the ON-OFF key in position “ground control panel” it is possible to select the type of power for the ground controls:
If ELECTRIC is selected and the ON-OFF key is kept active in position “ground controls” the 220V single-phase pump is
started;
If THERMIC is selected and the ON-OFF key is kept active in position “ground controls” the heat motor can be started.
Summary of Contents for AIRO R Series
Page 16: ...Use and Maintenance Manual R13 R17 Series Page 16 Fig 3...
Page 21: ...Use and Maintenance Manual R13 R17 Series Page 21 Fig 4...
Page 81: ...Use and Maintenance Manual R13 R17 Series Page 81...
Page 98: ...Use and Maintenance Manual R13 R17 Series Page 98...
Page 99: ...Use and Maintenance Manual R13 R17 Series Page 99 12 WIRING DIAGRAM 043 08 001...
Page 100: ...Use and Maintenance Manual R13 R17 Series Page 100 043 08 002...
Page 101: ...Use and Maintenance Manual R13 R17 Series Page 101...
Page 103: ...Use and Maintenance Manual R13 R17 Series Page 103 059 08 005 CA1...
Page 104: ...Use and Maintenance Manual R13 R17 Series Page 104 059 08 007 CR...
Page 105: ...Use and Maintenance Manual R13 R17 Series Page 105 059 08 001...
Page 106: ...Use and Maintenance Manual R13 R17 Series Page 106 059 08 006...
Page 107: ...Use and Maintenance Manual R13 R17 Series Page 107...
Page 108: ...Use and Maintenance Manual R13 R17 Series Page 108 043 08 017...
Page 109: ...Use and Maintenance Manual R13 R17 Series Page 109 059 08 012...