Heat motor start button (D)
Holding the ON-OFF key in position “ground controls” after selecting the THERMIC power, the heat motor can be started by
means of the relevant switch.
In “0” position the heat motor is off;
In “3 sec” position the plugs pre-heating takes place (only for Diesel motor);
In “Start” position the motor starts.
5.2.5.
User interface display (E)
The multifunction display for machine/user interface is used to:
Display the operation parameters of the machine during normal functioning or in the event of a fault;
working hours of heat motor (when thermic power is selected the working hours are displayed in the format
HOURS:MINUTES and final letter D);
Working hours of the single-phase or three-phase work pump (when 220V or 380V electric power is selected –at platform- the
working hours are displayed in the format HOURS:MINUTES and final letter E) –OPTIONAL-;
The user interface display is also used during any interventions by specialized personnel to calibrate/adjust
the working parameters of the machine. This function is not available to the user.
5.2.6.
Machine warning light on (G)
The green light is ON when the machine is turned ON and the ground control panel is enabled (the on/off key should be kept in
“turret” position).
5.2.7.
Heat motor warning lights (H,L,M and N) (DIESEL motor only).
These warning lights warn the user of any Diesel motor operational faults (models “D” and “ED”). One of these warning lights turns
ON when the motor is stopped. A “fault” message is sent to the operator on the platform (see paragraph “Platform control panel”)
Once the Diesel motor has stopped due to a problem signalled by one of these warning lights, the motor can no longer be re-
started until such problem has been solved.
5.2.8.
Platform control levers (O,P,Q,R,S,T,U)
The various levers shown in the figure allow the platform to be operated. According to the various signs the corresponding
movements are activated. These controls can be operated only if the on-off key is set to ON down (ground control panel selected).
We shall also remind you that the ground controls - except for JIB LIFTING/LOWERING - are to be used to operate the platform
only in emergency situations and must not be used for any other purposes.
Use the ground controls only in emergency situations to allow the platform to be lowered.
IT IS FORBIDDEN to use the ground control panel as a workstation when personnel is on the platform.
Summary of Contents for AIRO R Series
Page 16: ...Use and Maintenance Manual R13 R17 Series Page 16 Fig 3...
Page 21: ...Use and Maintenance Manual R13 R17 Series Page 21 Fig 4...
Page 81: ...Use and Maintenance Manual R13 R17 Series Page 81...
Page 98: ...Use and Maintenance Manual R13 R17 Series Page 98...
Page 99: ...Use and Maintenance Manual R13 R17 Series Page 99 12 WIRING DIAGRAM 043 08 001...
Page 100: ...Use and Maintenance Manual R13 R17 Series Page 100 043 08 002...
Page 101: ...Use and Maintenance Manual R13 R17 Series Page 101...
Page 103: ...Use and Maintenance Manual R13 R17 Series Page 103 059 08 005 CA1...
Page 104: ...Use and Maintenance Manual R13 R17 Series Page 104 059 08 007 CR...
Page 105: ...Use and Maintenance Manual R13 R17 Series Page 105 059 08 001...
Page 106: ...Use and Maintenance Manual R13 R17 Series Page 106 059 08 006...
Page 107: ...Use and Maintenance Manual R13 R17 Series Page 107...
Page 108: ...Use and Maintenance Manual R13 R17 Series Page 108 043 08 017...
Page 109: ...Use and Maintenance Manual R13 R17 Series Page 109 059 08 012...