Execute Standard: GB/T 7724-2008 

 

Accuracy Class

III, n=3000       error partition coefficient :

 pi =0.5

 

 

Input Sensitivity ≥ 1.

2uV/e 

 

A/D conversion mode:

 

Δ-Σ

  mode

24bit   

 

 

Load Cell Bridge Voltage: DC 5V, 1-

12pcs 350Ω resistance stain gauge l

oad cell. 

 

Load Cell Connection Mode: 6 wires (long distance compensation, about 50 meters) 

 

Display 256X64 dot matrix OLED   

 

Clock: clock can display year/moth/date, hour/minute/second, auto leap year, leap month, 

without effect by power off. 

 

Scoreboard interface: Current loop /RS232 output ,baud rate 600bps Transmission distance 

30 meters

 

 

Serial communication interface:   

 

Transmission communication interface  RS232  Transmission distance 

30 meters

 

Baud rate

  1200/2400/4800/9600/19200 is optional   

Printer interface 

 

standard parallel output port, can connect with

  KX

P1121

KX

P1131

LQ300K

+Ⅱ、

 

LQ1600K

LQ-680K

DS-300 and LQ-730K/630K/635K… 

 

Data storage:    

 

Vehicle number and tare weight 

:≤

1000pcs              weighing record 

1500 groups 

 

Power supply   

AC187~242V

50 Hz   

 

Work environment   

Work temperature:

0

℃~

40

       

 

 

  Work 

humidity

:≤

85

%(

RH

no condensation 

 

Storange environment   

Storage temperature 

:-

20

℃~

60

       

 

 

Storage temperature 

:≤

95

%(

RH

no condensation   

Dimension (mm)

   346 ×84 ×233 

The weight of indicator itself (Kg)

    about 3.5 

2

Installation

 

2.1 

Indicator Layout

 

X front panel   

                         

X back panel

 

 

                                           
 
 
 
 

Summary of Contents for TTA-01

Page 1: ...TIGER TTA 01 Weighing Indicator User manual Version Oct 2015...

Page 2: ...gas or flammable vapor areas or tank system with pressure keep indicator and load cell away from strong electric magnetic field corrosive substances and explosive materials do not sue strong solvents...

Page 3: ...istance 30 meters Serial communication interface Transmission communication interface RS232 Transmission distance 30 meters Baud rate 1200 2400 4800 9600 19200 is optional Printer interface standard p...

Page 4: ...hunder storm season proper lightning protection should be taken to protect the load cell and indicator from damaging by lighting and to ensure the personal safety to run of the weighing and related eq...

Page 5: ...scription Code 5 Connect to ground GND 1 RS485 A A 9 RS485 B B 3 RS232 receive RXD 2 RS232 send TXD Connect communication interface and PC side correctly or will break the indicator interface and PC s...

Page 6: ...eters of communication address baud rate communication mode 4 2 2 Print Settings Go into this menu it could set print type print format vehicle number and cargo number 4 2 3 Time Settings If the date...

Page 7: ...r Print the Report function if find there is a symbol like it means the printing data is not complete Appendix 1 serial communication data format All data is ASCII code and each byte could be 8bits da...

Page 8: ...ght the format is below Each frame is made up of 14 groups data a symbol or b h net weight value 6ofnumber and 1 decimal NOTICE XOR verify high four bits and low four bits confirme like below XOR high...

Page 9: ...C N GROSS TARE NET 0001 12 01 08 20 08 00 ZJ888FUK APPLE PIE 8000 1300 6700 0002 12 01 08 20 19 21 32D AK047 ORANGE 9000 1300 7700 0003 12 01 08 20 24 33 BMW86 SB BANANA 8600 1500 7100 Appendix 3 Fun...

Page 10: ......

Page 11: ...ing list Serial no Name and specifications Quan tity Remark 1 indicator 1pc 2 User manual 1pc 3 Technical manual 1pc 4 Certificate 1pc 5 7 core aviation plug 1pc 6 insurance tube 0 5A 1pc 7 Double AC...

Reviews: