background image

 

Instruction

 

No 

Description 

Code 

GROUND 

GND 

Current loop+(input) 

+OUT 

10 

Current loop-(output) 

-OUT 

11 

RS232 sending for remote 

display 

TXD 

 

Scoreboard output port cable of the indicator must connect with soreboard correctly. Otherwise, it would broke the 

output port of the indicator, or broke the scoreboard input port. Also it may break the indicator and scoreboard too .It 

shall use the dedicated connection cable. 

Scoreboard must connect to ground reliably, otherwise it may influence the indicator normal use, or may broke the 

load cell , indicator, scoreboard and printer. 

  
2.5 Connection to serial communication interface 

 

Instruction 

No 

Description 

Code 

Connect to ground 

GND 

RS485

A

 

RS485

B

 

RS232 receive 

RXD 

RS232 send 

TXD 

 

Connect communication interface and PC side correctly, or will break the indicator interface and PC side interface. 

▲If you want to connect 

with PC, it shall be done by professional person .If you have the computer technology and 

process edit performance, it would be better. Non-professional person can not do this. 

The indicator has RS232 serial communication interface, it could connect with computer. 

 

 

3

Display instruction 

   
 
 

 

 
 
 
4

Operation instruction   

Operation :use key

“←”“→”

to choose the menu or press number key to choose 

menu,press key ‘ENTER’ to go into it.All is English menu and English notice,if you 
have basic scale knowledge ,you could operate it easily. 

N.W 

Stable 

Zero 

Date

format:

YY-MM-DD

 

Time

format:

HH-MM-SS

 

Unit 

keyboard

 

identification 

Summary of Contents for TTA-01

Page 1: ...TIGER TTA 01 Weighing Indicator User manual Version Oct 2015...

Page 2: ...gas or flammable vapor areas or tank system with pressure keep indicator and load cell away from strong electric magnetic field corrosive substances and explosive materials do not sue strong solvents...

Page 3: ...istance 30 meters Serial communication interface Transmission communication interface RS232 Transmission distance 30 meters Baud rate 1200 2400 4800 9600 19200 is optional Printer interface standard p...

Page 4: ...hunder storm season proper lightning protection should be taken to protect the load cell and indicator from damaging by lighting and to ensure the personal safety to run of the weighing and related eq...

Page 5: ...scription Code 5 Connect to ground GND 1 RS485 A A 9 RS485 B B 3 RS232 receive RXD 2 RS232 send TXD Connect communication interface and PC side correctly or will break the indicator interface and PC s...

Page 6: ...eters of communication address baud rate communication mode 4 2 2 Print Settings Go into this menu it could set print type print format vehicle number and cargo number 4 2 3 Time Settings If the date...

Page 7: ...r Print the Report function if find there is a symbol like it means the printing data is not complete Appendix 1 serial communication data format All data is ASCII code and each byte could be 8bits da...

Page 8: ...ght the format is below Each frame is made up of 14 groups data a symbol or b h net weight value 6ofnumber and 1 decimal NOTICE XOR verify high four bits and low four bits confirme like below XOR high...

Page 9: ...C N GROSS TARE NET 0001 12 01 08 20 08 00 ZJ888FUK APPLE PIE 8000 1300 6700 0002 12 01 08 20 19 21 32D AK047 ORANGE 9000 1300 7700 0003 12 01 08 20 24 33 BMW86 SB BANANA 8600 1500 7100 Appendix 3 Fun...

Page 10: ......

Page 11: ...ing list Serial no Name and specifications Quan tity Remark 1 indicator 1pc 2 User manual 1pc 3 Technical manual 1pc 4 Certificate 1pc 5 7 core aviation plug 1pc 6 insurance tube 0 5A 1pc 7 Double AC...