INDICATOR USING NOTES 

 

 

 

Indicator ground wire must be complying with electrical safety regulations, junction box; load cell must be 

well grounded.   

 

Connection between digital load cell and indicator must be reliable, load cell shield wire must be grounded. 

▲ all cable does not allow plug / unplug when indicator is connecting to power supply, to protect indicator or 

load cell from electrostatic. 

▲ Thunderstorm season, system must have reliable lightning protection measures, to protect load cell and 

indicator. 

Make sure operators’ safety and weighing equipments running safely. 

▲ limited using for flammable gas, or flammable vapor areas, or tank system with pressure.

 

▲ keep indicator and load cell away from strong electric magnetic field, corrosive substances an

d explosive 

materials. 

▲ do not sue strong solvents( such as: benzene, nitro

-class oil) to clean the cover. 

▲ do not inject liquid or other conductive particles into indicator.

 

▲ without technical supervision department’s promise, no one can open the seals

, or calibrate.. 

  to ensure indicator display clearly, and work longer, do not use it under direct sunlight, and put it stable. 

  indicator should be away from dust, vibration, wet environment. 

  before plugging/unplugging, pls cut off indicator or other equipments’ power. 

  connecting each connector as the manual book. 

  That indicator is precision measuring instrument, to ensure accuracy, do not open it without authorization. 

  exceeding maintenance time, factory should charge for repairing. 

 
 

 

1

Technical Parameters: 

Summary of Contents for TTA-01

Page 1: ...TIGER TTA 01 Weighing Indicator User manual Version Oct 2015...

Page 2: ...gas or flammable vapor areas or tank system with pressure keep indicator and load cell away from strong electric magnetic field corrosive substances and explosive materials do not sue strong solvents...

Page 3: ...istance 30 meters Serial communication interface Transmission communication interface RS232 Transmission distance 30 meters Baud rate 1200 2400 4800 9600 19200 is optional Printer interface standard p...

Page 4: ...hunder storm season proper lightning protection should be taken to protect the load cell and indicator from damaging by lighting and to ensure the personal safety to run of the weighing and related eq...

Page 5: ...scription Code 5 Connect to ground GND 1 RS485 A A 9 RS485 B B 3 RS232 receive RXD 2 RS232 send TXD Connect communication interface and PC side correctly or will break the indicator interface and PC s...

Page 6: ...eters of communication address baud rate communication mode 4 2 2 Print Settings Go into this menu it could set print type print format vehicle number and cargo number 4 2 3 Time Settings If the date...

Page 7: ...r Print the Report function if find there is a symbol like it means the printing data is not complete Appendix 1 serial communication data format All data is ASCII code and each byte could be 8bits da...

Page 8: ...ght the format is below Each frame is made up of 14 groups data a symbol or b h net weight value 6ofnumber and 1 decimal NOTICE XOR verify high four bits and low four bits confirme like below XOR high...

Page 9: ...C N GROSS TARE NET 0001 12 01 08 20 08 00 ZJ888FUK APPLE PIE 8000 1300 6700 0002 12 01 08 20 19 21 32D AK047 ORANGE 9000 1300 7700 0003 12 01 08 20 24 33 BMW86 SB BANANA 8600 1500 7100 Appendix 3 Fun...

Page 10: ......

Page 11: ...ing list Serial no Name and specifications Quan tity Remark 1 indicator 1pc 2 User manual 1pc 3 Technical manual 1pc 4 Certificate 1pc 5 7 core aviation plug 1pc 6 insurance tube 0 5A 1pc 7 Double AC...

Reviews: