background image

3

There are three modes of saving : 

When the vehicle is empty, save data, and then the vehicle is full, save data. 
When the vehicle is full, save data ,and then the vehicle is empty, save data. 
Only after two times saving, the data is a complete group data. 
And when the vehicle is full and net weight identifier light on ,one time saving could be a complete group data. 
 

5.  Saving operation   

Press key [PRINT],the indicator would display date ,time and the weight data, user could input vehicle number and 

cargo information after confirmation, if there is no this vehicle number and cargo info ,it would make a record here. if 
there has this vehicle number ,then it would make record more detailed and print. 
 
6.   During print period, if there is error, or no paper, it could not print normally, after eliminate the error, and press key 
[REPRINT] to print. 
 
7.    Each time after weighing, it would add up, press key [A.P] which could print the total weight,after operation ,it 
would add up again from beginning. 

When data 

is not stable or net weight is ≤0,it could not do saving operation.

 

Notice:If use “REPRINT” or “Print the Report”function ,if find there is a symbol like “*”,it means the printing 
data is not complete. 

 

Appendix 1: serial communication data format 

All data is ASCII code, and each byte could be 8bits data , no odd or even number. Bit 1 is stopping bit,(8,N,1) to 
communicate. Communication mode is like below : 

1 Continue mode 

 

The data sent is the weight value the indicator display(net weight or gross weight).Each frame data is made up of 12 groups 
data. 

Byte number   

NOTICE   

02(XON) 

                START   

+ OR -                     Symbol bit   

Weighing data                  High bit   

 

 

Weighing data                       

 

 

 

Weighing data                       

 

Weighing data                   Low bit                    

Decimal bit number             from right to left (

0

4

                                      

10 

XOR verify   

High four bits   

XOR

2

3

⊕……⊕

8

9                    

 

11 

XOR verify 

Low four bits 

12 

03(X0FF) 

                END   

 

2 ORDER mode   

Indicator would show one data according the order from the PC. Each time PC send an order, the indicator would show 

one frame data. 

PC sending order   

Byte number 

NOTICE   

02(XON) 

                

 

START 

A

Z                  

 

 

Address number   

A

I  

Order A

Shake hand  

 

 

ORDER B

read gross weight  ORDER 

C

read tare weight 

 

 

Order D

read net weight   

 

ORDER E

read vehicale number

 

ORDER F

read cargo number   

 

 

Order G

clear all data 

ORDER H

SET ZERO    ORDER I:TARE       

XOR verify

 

High four bits   

XOR 

2

3

⊕……⊕

( n-1 )

XOR verify

 

Low four bits 

03(X0FF)             

 

 

END   

 
INDICATOR OUTPUT CONTENTS   

Byte number 

NOTICE   

02(XON)                  

 

START 

Summary of Contents for TTA-01

Page 1: ...TIGER TTA 01 Weighing Indicator User manual Version Oct 2015...

Page 2: ...gas or flammable vapor areas or tank system with pressure keep indicator and load cell away from strong electric magnetic field corrosive substances and explosive materials do not sue strong solvents...

Page 3: ...istance 30 meters Serial communication interface Transmission communication interface RS232 Transmission distance 30 meters Baud rate 1200 2400 4800 9600 19200 is optional Printer interface standard p...

Page 4: ...hunder storm season proper lightning protection should be taken to protect the load cell and indicator from damaging by lighting and to ensure the personal safety to run of the weighing and related eq...

Page 5: ...scription Code 5 Connect to ground GND 1 RS485 A A 9 RS485 B B 3 RS232 receive RXD 2 RS232 send TXD Connect communication interface and PC side correctly or will break the indicator interface and PC s...

Page 6: ...eters of communication address baud rate communication mode 4 2 2 Print Settings Go into this menu it could set print type print format vehicle number and cargo number 4 2 3 Time Settings If the date...

Page 7: ...r Print the Report function if find there is a symbol like it means the printing data is not complete Appendix 1 serial communication data format All data is ASCII code and each byte could be 8bits da...

Page 8: ...ght the format is below Each frame is made up of 14 groups data a symbol or b h net weight value 6ofnumber and 1 decimal NOTICE XOR verify high four bits and low four bits confirme like below XOR high...

Page 9: ...C N GROSS TARE NET 0001 12 01 08 20 08 00 ZJ888FUK APPLE PIE 8000 1300 6700 0002 12 01 08 20 19 21 32D AK047 ORANGE 9000 1300 7700 0003 12 01 08 20 24 33 BMW86 SB BANANA 8600 1500 7100 Appendix 3 Fun...

Page 10: ......

Page 11: ...ing list Serial no Name and specifications Quan tity Remark 1 indicator 1pc 2 User manual 1pc 3 Technical manual 1pc 4 Certificate 1pc 5 7 core aviation plug 1pc 6 insurance tube 0 5A 1pc 7 Double AC...

Reviews: