Owner’s Manual
E
2010 THYSSENKRUPP ELEVATOR
Printed in USA February, 2010
Signa 4 Signal Fixtures-61
DMG Contact Block Removal Procedure
1. Ensure that the back of the push button panel is visible.
See Figure 2, Step 1.
2. Pull down the contact block past the bottom tab. See
Figure 1 and Figure 2, Step 2.
Figure 1 - Push Button Assembly
Pull Contact Block Down
Bottom Tab
3. Pull the lower part of the contact block out away from the
panel to release the bottom tab. See Figure 2, Step 3.
4. Move the contact block up to release the top tab. See
Figure 2, Step 4.
Figure 2 - Contact Block Removal
Step 1
Step 2
Step 3
Step 4