![ThyssenKrupp TAC 32 Owner'S Manual Download Page 156](http://html1.mh-extra.com/html/thyssenkrupp/tac-32/tac-32_owners-manual_1113948156.webp)
Owner’s Manual
E
2010 THYSSENKRUPP ELEVATOR
Printed in USA February, 2010
Door Protection-4
Trouble-Shooting LEDs
There are two red trouble-shooting LEDs positioned near the
top of the TX detector. The states they can indicate are shown
below.
Figure 7 - Troubleshooting LEDs
LED
Status
Possible Cause
OFF
No Power
OFF
FLASHING
TX/RX connection open crcuit
OFF
ON
Triggered state,
OFF
obstruction between detectors
ON
Normal scanning state
ON
SYSTEM CONNECTION
For trouble-free installation we recommend installing the 640
system with a Memco 280 power supply. However in many
situations the 640 can be directly connected to the lift
controller or door operator.
Using a Memco Power Supply
A Memco power supply eliminates concern about the
electrical environment into which the 640 is being installed
and simplifies wiring. (See Figure 8.)
Figure 8 - MEMCO Connections