10.
Emergency devices
Emergency stop
To stop the Platform Lift, just press the emergency button (red button) on the push button panel. To
start the Platform Lift again, turn the mushroom-head emergency button clockwise.
Emergency lighting in the event of a black-out
In the event of a black-out, interior lift lighting dims. If the cabin does not contain a display, a
special emergency light will activate.
Emergency battery
Inside of the electrical control panel there is an emergency battery group, which in the event of a
power outage, sees to providing electrical power to the Platform Lift. The battery unit allows the
operation of those solenoid valves necessary for electrical emergency descent. The batteries are
charged by an internal battery charger on the electrical switch panel. If the batteries are discharged
or damaged, if the platform is stopped at a floor, the run commands, both inside and outside, are
disabled.
The integrity of the battery group must be checked and verified periodically.
Emergency descent
In the event of a black-out, it is possible to move down to a lower floor than where the lift is by
pressing the lower floor descent button. Once the floor has been reached, the lift cannot be used
until power has been restored.
Manual emergency descent
This procedure must be carried out only by educated persons.
In the event of a power outage and the non-operation of the emergency electrical descent, an
expert operator may have the platform descend to the next floor down pushing and holding down
the button located on the solenoid valve found on the hydraulic control unit.
Emergency descent
Emergency descent
Hydraulic unit “type 1“
Hydraulic unit “type 2“
Summary of Contents for gulliver