14
This document is the property of THRILL INTERNATIONAL and may not be reproduced without the company’s prior consent.
Connection
block
Open
gas flow
Close
gas flow
CAUTION
The dip tube inside the cylinder must be designed to reach a position approximately 2 mm
from the bottom of the cylinder to ensure better use of the carbon dioxide in its liquid
state. The use of cylinders not fitted with the appropriate dip tube may hinder the proper
functioning of the appliance and in the event of machine failure resulting from such improper
use, the appliance will not be covered by the warranty.
SAFETY WARNING! Under no circumstances must the gas cylinders used with this appliance
be placed in the vicinity of heat sources or in direct sunlight. ALWAYS ensure that ambient
temperatures do not exceed 40 ° C.
5.2. CONNECTING THE GAS CYLINDER
While the battery is charging, the CO2 cylinder can be connected to the appliance.
To connect the cylinder, follow the steps listed below:
1) Install the cylinder in the desired location, away from naked flames or sources of heat
2) Position the ring nut/flange on the connector tube against the connection thread on the
cylinder
3) Manually screw the connection ring nut/flange to the thread by rotating clockwise until
tight, finish tightening the nut using a No. 27 spanner.
4) Slowly release the CO2 cylinder valve by turning the knob anti-clockwise until it is fully open
and the mechanism locks.
See diagrams below:
5) If, when opening the valve, you can hear CO2 escaping, close the valve, unscrew the
connection, check there is no dust or dirt between the two conical surfaces and following
the steps described above, re-screw the connector to the cylinder.
Before using the appliance, the battery charger and power adapter must be unplugged and
both stored in a safe place for subsequent reuse.
When the need arises to replace the CO2 cylinder, turn off the gas supply from the cylinder and
run the machine on an empty cycle to relieve the gas pressure in the tube, before unscrewing the
connector. Then proceed with the connection of the full cylinder as described previously.