GLASSWARE SANITIZING APPLIANCE
User and maintenance manual
REV. 4
13
EN
GLI
SH
Sanitizing
machine
On/off switch
Battery
charger
connection
The battery takes between 8 and 16 hours to recharge and once fully charged is sufficient to
operate the appliance with a 10 litre CO2 cylinder.
When the recharge is completed, the charger must be removed from both the appliance itself
and from the socket and stored in a safe, protected place. The appliance is fitted with four
rubber feet so that it can be placed firmly on a worktop as illustrated below:
Appliance
identification
plate
Rubber
support feet
To ensure proper functioning and the safety of those operating the appliance, the machine must be
placed on a dry, smooth, flat surface. It must then be connected to a gas cylinder (with dip tube) filled
with E290 food grade CO2 (PLEASE REFER TO THE TECHNICAL DATA SPECIFICATIONS ON CHAPTER 4.3).
Be careful not to excessively bend (minimum bend radius 5 cm) or squash the black supply hose
connecting the cylinder to the appliance, so as to avoid a reduction in or discontinuation of the
CO2 gas supply to the glasses.
DANGER
Use only carbon dioxide that is specified for food use or is marked ‘E290’. The use of
other types of carbon dioxide (e.g. industrial use CO2) cannot guarantee the optimal
levels of hygiene that the appliance can provide and may impart an unpleasant odour to
the glasses thus treated.
DANGER
The machine must always be used in ventilated environments as continued use of the
machine in closed, unventilated spaces may lead to a build-up in the percentage of CO2
present to above 0.5%, which is considered to be potentially hazardous to health.
Recharger connection for Thrill CUBE model