3.2
Parts List - Accessories
A complete wavefront analyzing system consist of a WFS150 or WFS150C
sensor, a USB2.0 cable and an PC or laptop. You don't have to install an
additional card into your PC and you don't need external power supply.
The shipping package contains:
·
Wavefront Sensor instrument as an external measurement head with dust
cover
·
Mounting adapter plate and 4 mounting screws M3x6
·
USB2.0 high speed cable USB A to Mini USB B, 1,5 m
·
CD-ROM with the required driver and application software included
·
Wavefront Sensor operating manual
The Wavefront sensor comes with different configurations depending on the order
code.
Two Wavefront Sensor Models
There are two different versions available which differ in the implemented
microlens array (MLA, see data here
) and its distance to the CCD
camera sensor.
·
WFS150
uses an anti-reflection (AR) coated MLA that reduces the reflection
from the array to
below 1% within the wavelength range 400 - 900 nm
.
Note, that the total reflection from the entire instrument can be higher due to
reflection from the CCD cover glass and chip itself.
This model is well suited
for applications that do not tolerate back-
reflections
back into the measurement setup, for instance because it
contains a laser without an isolator but parallel beam and long coherence
length. Use this model if other ways for preventing back-reflection line tilting
the Wavefront Sensor with respect to the input beam are not feasible.
·
WFS150C
uses a MLA with a chrome mask on it that prevents light going in
between the microlenses directly to the CCD detector. This increases the
image contrast of the detected spotfield and improves the instrument
accuracy, especially in case of strong wavefront deformations. The
wavelength range is not restricted by an AR coating and covers the full
sensitivity range of the Silicon CCD detector
200 - 1100 nm
(with largely
reduced sensitivity at the edges). Take into account that such a chrome
mask that cannot be anti-reflection coated may
reflect up to 25%
of the
input light back to your measurement setup. It can be helpful to tilt the
sensor a bit or insert an attenuator in order to reduce the amount of light
reflected back into your measurement setup.
Both models are usable within different wavelength ranges. Due to the AR
coating used inside WFS150 it is best suited within this range but not outside
where the AR coating may have reflective properties! See the following
for details.
Summary of Contents for WFS150
Page 1: ...2007 Operation Manual Thorlabs Instrumentation Optical Wavefront Sensor WFS150 WFS150C...
Page 2: ...Version Date 1 2 December 2007 2007 Thorlabs GmbH 2007 Thorlabs GmbH...
Page 6: ...General WFS150 WFS150C Manual Part I...
Page 10: ...Getting Started WFS150 WFS150C Manual Part II...
Page 25: ...Description WFS150 WFS150C Manual Part III...
Page 35: ...Operating Instruction WFS150 WFS150C Manual Part IV...
Page 103: ...Service and Maintenance WFS150 WFS150C Manual Part V...
Page 107: ...Listings WFS150 WFS150C Manual Part VI...
Page 110: ...Appendix WFS150 WFS150C Manual Part VII...
Page 116: ...114 WFS150 WFS150C Manual 2007 Thorlabs GmbH Typical Response of the CCD camera...
Page 117: ...115 Appendix 2007 Thorlabs GmbH 7 4 Wavefront Sensor Drawing...
Page 123: ......