7
Installation (Continued)
Step 2b: Install Casters (options)
A set of four casters is packed with units ordered with casters (instead of legs).
A threaded leg pad is fastened to the base frame at each corner. Each caster gas a corresponding mating
thread. The caster can be adjusted to overcome a slightly uneven floor. Casters are provided with a Zerk fitting
for proper lubrication when required.
1.
Raise unit sufficiently to allow leg pads and casters to be attached. For safety, “shore up” and support the
unit with an adequate blocking arrangement strong enough to support the load.
2.
Attach the four leg pads to the bottom of the range using the lock washers and machine screws. The
mounting holes are pre-drilled and threaded.
3.
Screw the caster into the holes in the centers of the leg pads. Install the casters that have a locking brake
under the front of the unit.
4.
Lower unit gently onto a level surface. Never drop or allow the unit to fall.
5.
Use a level to make sure that the range surface is level. The casters can be screwed in or out to lower or
raise each corner of the range. After the unit has been leveled, tighten the lock nuts.
6.
Secure the restraining-device bracket to a wall stud located as close as possible to the appliance connector
inlet and outlet connections. Use four screws.
NOTICE
Adequate means must be provided to limit the movement of the appliance without depending on the
connector and the quick-disconnect device or its associated piping to limit the appliance movement.
The restraining means should be attached to a frame member on the back of the unit.