17
Adjustments (Continued)
CONVERTING FROM LPG TO NG AND VICE-VERSA
1.
Turn-off the pilot.
2.
Shut-off the main isolation valve and follow the lock-out/tag-out procedure.
3.
Remove the gas regulator.
4.
Remove the converter cover from the regulator. Use a 22mm spanner.
5.
Pull-out the converter and position it to your desired gas type.
6.
Install the converter cover to the regulator.
7.
Re-install the regulator to the unit. Follow the direction of the arrow on the regulator when installing.
8.
Replace the burner injectors. Follow the burner injector removal procedure. See the parts list for
injector orifice size for specific gas type.
9.
Replace the ODS injector. Follow the ODS injector removal procedure. See parts list for injector orifice
size for specific gas type.
OPENING OF THE RANGE TOP FOR PARTS REPLACEMENT
1.
Remove the trivets.
2.
Remove the griddle plate assembly (for TR-4F-G12F model)
3.
Remove the control knobs.
4.
Remove the thermostat control knob. Loosen the lock screw at the knob side.
5.
Remove the griddle drip tray. (for TR-4F-G12F model)
6.
Remove the mounting screws of the control panel cover. For TR-4F-G12F model, there are two
mounting screws inside the griddle drip tray slot that must be removed to fully remove the control
panel cover.
7.
Remove the piezo igniter wire.
8.
Remove the control rack mounting screws.
9.
Remove the control rack.