23
Troubleshooting (Continued)
Continued from Previous Page
Place a digital surface temperature
instrument in the center of the griddle.
Allow reading to stabilize to 150
℃
Record this temperature.
Move the surface measurement instrument
in the center of the griddle over each burner.
Record the temperatures.
Average the temperature of each burner
reading.
To adjust the temperature, locate the center
of the thermostat.
Scrape the paint seal off of the screw.
NOTE!
There are arrows around the screw
indicating (H) to increase and (L) to
decrease the temperature.
NOTE!
Only turn this screw by small
increments.
While holding the knobs at 150
℃
setting,
push the screw in and turn it in the direction
indicated to change the temperature.
Repeat this procedure at each burner until the
temperature stabilizes to within 30
℃
of the set
temperature
If the temperature cannot be set to within 30
℃
replace the thermostat and reset.
NOTE: If the user is dissatisfied with the
griddle temperature recovery time.
Remove the knobs, bezels and control panel.
Turn the bypass screw counter clockwise to
fully open the bypass flame.
Reinstall the knobs, bezels and cover panel.
Reinstall the silver in the knob center.
Recalibrate the thermostat.