19
Troubleshooting
RANGE TOP BURNER
TROUBLESHOOTING
Common checks of all top configurations.
Check that the burners are set level in the
support brackets.
Check that the burners are clean and all ports
are clear.
Remove each burner and check that the
venture is clean and free of buildup and
debris.
With each burner removed check that the
orifice size is correct and clean and free of
buildup and debris.
Remove the knobs and carefully lower the
top valve cover panel.
CAUTION!
Wiring
attached behind panel on C.O base models.
Check that each burner valve and orifice is
in alignment with the burner
Shut off the main gas supply.
Install a pressure tap in the main gas line
before the range pressure regulator and
install a manometer.
Turn on the main gas supply.
Re-light all pilots.
NOTE
: Griddle Tops
NOTE
: Griddles and Hot Tops must be raised
and secured or removed.
CAUTION!
Before raising or removing
Griddle Tops.
Remove the knobs and carefully lower the
control panel.
CAUTION!
Wiring attached
behind panel.
Light all burners on the range.
NOTE
: Leave
the oven door open.
Observe the inlet pressure.
Inlet pressures for gases are:
See rating label.
If the inlet pressure is low, all equipment on the
main gas line should be lit and the pressure
adjusted
Shut off the range burners and main gas and
remove the pressure tap.
Pull the Griddle thermostat bulbs out of the
tubes.
Continues on next page.