4.6.9  Control option LLX

In addition to all of the features included in the LXX version (section 4.6.8), LLX also includes end of 

stroke indication. These outputs can be used to provide feedback that the actuator has reached it’s 

mechanical minimum or maximum stroke. 

Since these outputs are current sinking open collector type of outputs, they will each require an external 

pull-up resistor to operate effectively.

Power the actuator by connecting red to + Vdc and black to - Vdc in the power cable. To extend the 

actuator apply +Vdc to violet and to retract apply +Vdc to orange in the signal cable while applying -Vdc 

to grey.

F Fuse

S1  Extend switch 

S2   Retract switch

R1  Pull-up resistor

R2  Pull-up resistor

LLX Control Option Specifications

Input voltage

MD12

MD24

[Vdc]

9 - 16

18 - 32

Max. actuator current draw

[A] see product label

Extend / retract input voltage [Vdc]

9 - 32

Extend / retract input current [mA]

6 - 22

End-of-stroke output type

open collector

End-of-stroke output max. [Vdc] 

voltage

32

End-of-stroke output max. [mA] 

current

25

not used

fully extended

indication output

fully retracted

indication output

not used

- Vdc

red

black

white

blue

orange

violet

brown

grey

red/white

black/white

 ext/ret + Vdc

Summary of Contents for Electrak MD Series

Page 1: ...Thomson Electrak MD Electric Linear Actuator Installation Manual Edition 2020 02 www thomsonlinear com...

Page 2: ...as to the suitability of the product for any particular use or purpose For a copy of the entire warranty for this product that is contained in our standard terms and conditions of sale please go to ht...

Page 3: ...3 1 EC Declaration of conformity 5 4 Installation 6 4 1 Product label 6 4 2 Terminology 6 4 3 Operation environment 6 4 4 Mechanical installation 7 4 5 Electrical installation 10 4 6 Control options...

Page 4: ...packaging supplied by Thomson The temperature during transportation and storage must be between 40 to 85 C 40 to 185 F Avoid shocks to the package If the package is damaged check the actuator for vis...

Page 5: ...in any way and notify an appropriate person so that corrective actions can be taken Never open the actuator as that will compromise the sealing and the function of the actuator There are no serviceabl...

Page 6: ...please provide the serial number manufacturing date and the designation of the actuator s in question You can also use the QR code on the label to directly access Electrak MD information on www thomso...

Page 7: ...sidered to ensure it does not create harm 4 4 2 Basic installation considerations 1 Only mount the actuator using the holes in the rear a and front b adapters Check the model number on the actuator pr...

Page 8: ...able connector cover plate 1 The cover plate is held in place by a screw M2 5 with Torx T8 head that can be accessed through the hole in the top of the cover plate a Keep in mind to mount the actuator...

Page 9: ...ustomer connections In the other end the cable is integrated in to the cable connector cover plate b section 4 4 4 The plug in connector allows replacing the actuator without disconnecting the flying...

Page 10: ...ed If using an AC powered power supply it must be sized to handle the inrush current batteries typically have no problem delivering the inrush current Also contacts switches and relays must be sized a...

Page 11: ...od attempted to use the control will either keep the speed stop or be permanently damaged and cause malfunction 4 6 3 How to determine the control option Electrak MD is equipped with one of the contro...

Page 12: ...blue orange violet brown grey red white black white XXX Control Option Specifications Input voltage MD12 MD24 Vdc 9 16 18 32 Max actuator current draw A see product label F Fuse S1 Double pole double...

Page 13: ...the current move is finished in the situation where voltage or temperature are outside their normal operating ranges Once within the normal operating range the actuator will automatically reset and n...

Page 14: ...ontrol Option Specifications Input voltage MD12 MD24 Vdc 9 16 18 32 Max actuator current draw A see product label Potentiometer type wirewound Potentiometer max input voltage Vdc 32 Potentiometer max...

Page 15: ...ator and less the 2 mA for a 24 Vdc actuator The sleep mode will exit and return to normal operation when the next move command is received Dynamic braking throughout the entire stroke length whenever...

Page 16: ...d black to Vdc in the power cable To extend the actuator apply Vdc to violet and to retract apply Vdc to orange in the signal cable while applying Vdc to grey F Fuse S1 Extend switch S2 Retract switch...

Page 17: ...Fuse S1 Extend switch S2 Retract switch LXP Control Option Specifications Input voltage MD12 MD24 Vdc 9 16 18 32 Max actuator current draw A see product label Potentiometer type wirewound Potentiomet...

Page 18: ...fications Input voltage MD12 MD24 Vdc 9 16 18 32 Max actuator current draw A see product label Potentiometer type wirewound Potentiometer max input voltage Vdc 32 Potentiometer max power W 1 Potentiom...

Page 19: ...nd by applying Vdc to pin 6 violet wire and to retract by by applying Vdc to pin 5 orange wire When this is done the actuator will move with its maximum allowed settings 4 6 12 2 CAN Bus SAE J1939 ins...

Page 20: ...elected address the actuator will continue to request other addresses until it finds one that it can claim 2 The Electrak MD device can also use the commanded address PGN to select a specified address...

Page 21: ...o set a current at which the actuator will cease motion In the event a force is applied to the actuator that causes the motor current to exceed this settable value for more than 50 ms the actuator wil...

Page 22: ...ances or play in the actuator Range 0 0 mm to 300 0 mm Resolution 0 1 mm bit 0 offset 5 2 5 2 Measured current This 9 bit signal is used to inform the user of the actual current being drawn used by th...

Page 23: ...vibration being applied to the actuator 5 2 5 9 Parameter flag This 1 bit signal is used to inform the user that one of the parameter signals in the ACM is outside the allowed parameters the specific...

Page 24: ...fatal error message The actuator has encountered an uncommanded change in the stroke feedback device potentiometer The user can reset the actuator first to try and clear the error but if that does not...

Page 25: ...oad duty cycle 25 C see product label Restraining torque Nm lbf in 0 internally restrained Motor leads cross section mm2 AWG 0 75 18 Signal leads cross section mm2 AWG 0 35 22 Cable length depending o...

Page 26: ...dular Control System options XXX internal end of stroke limit switches XXP XXX analog potentiometer position output EXX Electronic Monitoring Package EXP EXX analog potentiometer position output LXX E...

Page 27: ...Thomson Thomson Electrak MD Actuator Installation Manual 2020 02 27...

Page 28: ...llo 95 97 20834 Nova Milanese MB Phone 39 0362 366406 Fax 39 0362 276790 E mail sales italy thomsonlinear com Spain Thomson E mail sales esm thomsonlinear com Sweden Thomson Estridsv g 10 29109 Kristi...

Reviews: