4.6.9 Control option LLX
In addition to all of the features included in the LXX version (section 4.6.8), LLX also includes end of
stroke indication. These outputs can be used to provide feedback that the actuator has reached it’s
mechanical minimum or maximum stroke.
Since these outputs are current sinking open collector type of outputs, they will each require an external
pull-up resistor to operate effectively.
Power the actuator by connecting red to + Vdc and black to - Vdc in the power cable. To extend the
actuator apply +Vdc to violet and to retract apply +Vdc to orange in the signal cable while applying -Vdc
to grey.
F Fuse
S1 Extend switch
S2 Retract switch
R1 Pull-up resistor
R2 Pull-up resistor
LLX Control Option Specifications
Input voltage
MD12
MD24
[Vdc]
9 - 16
18 - 32
Max. actuator current draw
[A] see product label
Extend / retract input voltage [Vdc]
9 - 32
Extend / retract input current [mA]
6 - 22
End-of-stroke output type
open collector
End-of-stroke output max. [Vdc]
voltage
32
End-of-stroke output max. [mA]
current
25
not used
fully extended
indication output
fully retracted
indication output
not used
- Vdc
red
black
white
blue
orange
violet
brown
grey
red/white
black/white
ext/ret + Vdc