THOMSON Electrak MD Series Installation Manual Download Page 28

Electrak_MD_Installation_Operation_MNEN-0009-01| 20200228TJ

Specifications are subject to change without notice. It is the responsibility of the product user to determine the suitability of 

this product for a specific application. All trademarks property of their respective owners. ©2020 Thomson Industries, Inc.

www.thomsonlinear.com

USA, CANADA and MEXICO

Thomson

203A West Rock Road

Radford, VA 24141, USA

Phone: 1-540-633-3549

Fax: 1-540-633-0294

E-mail: [email protected]

Literature: literature.thomsonlinear.com 

E

UROPE

United Kingdom

Thomson

Office 9, The Barns

Caddsdown Business Park

Bideford, Devon, EX39 3BT

Phone: +44 1271 334 500

E-mail: [email protected]

Germany

Thomson

Nürtinger Straße 70

72649 Wolfschlugen

Phone: +49 7022 504 403

Fax: +49 7022 504 405

E-mail: [email protected]

France

Thomson

Phone: +33 243 50 03 30

Fax: +33 243 50 03 39

E-mail: [email protected] 

Italy

Thomson

Via per Cinisello 95/97

20834 Nova Milanese (MB)

Phone: +39 0362 366406

Fax: +39 0362 276790

E-mail: [email protected]

Spain

Thomson

E-mail: [email protected]

Sweden

Thomson

Estridsväg 10

29109 Kristianstad

Phone: +46 44 24 67 00

Fax: +46 44 24 40 85

E-mail: [email protected]

 
 
 

ASIA

 

Asia Pacific

 

Thomson 

E-mail: [email protected]  

 

China

Thomson

Rm 805, Scitech Tower

22 Jianguomen Wai Street

Beijing 100004

Phone: +86 400 606 1805

Fax: +86 10 6515 0263

E-mail: [email protected]

India

Thomson

c/o Portescap India Pvt Ltd

1 E, first floor, Arena House

Road no 12, Marol Industrial Area, 

Andheri (E), Mumbai 400093 India

E-mail: [email protected] 

Japan

Thomson

Minami-Kaneden 2-12-23, Suita

Osaka 564-0044 Japan

Phone: +81 6 6386 8001

Fax: +81 6 6386 5022

E-mail: [email protected]

South Korea

Thomson

3033 ASEM Tower (Samsung-dong) 

517 Yeongdong-daero

Gangnam-gu, Seoul, South Korea (06164)

Phone: + 82 2 6001 3223 & 3244

E-mail: [email protected]

 

SOUTH AMERICA

 

Brazil

 

Thomson 

Av. João Paulo Ablas, 2970 

Jardim da Glória - Cotia SP - CEP: 06711-250 

Phone: +55 11 4615 6300 

E-mail: [email protected]

 

Summary of Contents for Electrak MD Series

Page 1: ...Thomson Electrak MD Electric Linear Actuator Installation Manual Edition 2020 02 www thomsonlinear com...

Page 2: ...as to the suitability of the product for any particular use or purpose For a copy of the entire warranty for this product that is contained in our standard terms and conditions of sale please go to ht...

Page 3: ...3 1 EC Declaration of conformity 5 4 Installation 6 4 1 Product label 6 4 2 Terminology 6 4 3 Operation environment 6 4 4 Mechanical installation 7 4 5 Electrical installation 10 4 6 Control options...

Page 4: ...packaging supplied by Thomson The temperature during transportation and storage must be between 40 to 85 C 40 to 185 F Avoid shocks to the package If the package is damaged check the actuator for vis...

Page 5: ...in any way and notify an appropriate person so that corrective actions can be taken Never open the actuator as that will compromise the sealing and the function of the actuator There are no serviceabl...

Page 6: ...please provide the serial number manufacturing date and the designation of the actuator s in question You can also use the QR code on the label to directly access Electrak MD information on www thomso...

Page 7: ...sidered to ensure it does not create harm 4 4 2 Basic installation considerations 1 Only mount the actuator using the holes in the rear a and front b adapters Check the model number on the actuator pr...

Page 8: ...able connector cover plate 1 The cover plate is held in place by a screw M2 5 with Torx T8 head that can be accessed through the hole in the top of the cover plate a Keep in mind to mount the actuator...

Page 9: ...ustomer connections In the other end the cable is integrated in to the cable connector cover plate b section 4 4 4 The plug in connector allows replacing the actuator without disconnecting the flying...

Page 10: ...ed If using an AC powered power supply it must be sized to handle the inrush current batteries typically have no problem delivering the inrush current Also contacts switches and relays must be sized a...

Page 11: ...od attempted to use the control will either keep the speed stop or be permanently damaged and cause malfunction 4 6 3 How to determine the control option Electrak MD is equipped with one of the contro...

Page 12: ...blue orange violet brown grey red white black white XXX Control Option Specifications Input voltage MD12 MD24 Vdc 9 16 18 32 Max actuator current draw A see product label F Fuse S1 Double pole double...

Page 13: ...the current move is finished in the situation where voltage or temperature are outside their normal operating ranges Once within the normal operating range the actuator will automatically reset and n...

Page 14: ...ontrol Option Specifications Input voltage MD12 MD24 Vdc 9 16 18 32 Max actuator current draw A see product label Potentiometer type wirewound Potentiometer max input voltage Vdc 32 Potentiometer max...

Page 15: ...ator and less the 2 mA for a 24 Vdc actuator The sleep mode will exit and return to normal operation when the next move command is received Dynamic braking throughout the entire stroke length whenever...

Page 16: ...d black to Vdc in the power cable To extend the actuator apply Vdc to violet and to retract apply Vdc to orange in the signal cable while applying Vdc to grey F Fuse S1 Extend switch S2 Retract switch...

Page 17: ...Fuse S1 Extend switch S2 Retract switch LXP Control Option Specifications Input voltage MD12 MD24 Vdc 9 16 18 32 Max actuator current draw A see product label Potentiometer type wirewound Potentiomet...

Page 18: ...fications Input voltage MD12 MD24 Vdc 9 16 18 32 Max actuator current draw A see product label Potentiometer type wirewound Potentiometer max input voltage Vdc 32 Potentiometer max power W 1 Potentiom...

Page 19: ...nd by applying Vdc to pin 6 violet wire and to retract by by applying Vdc to pin 5 orange wire When this is done the actuator will move with its maximum allowed settings 4 6 12 2 CAN Bus SAE J1939 ins...

Page 20: ...elected address the actuator will continue to request other addresses until it finds one that it can claim 2 The Electrak MD device can also use the commanded address PGN to select a specified address...

Page 21: ...o set a current at which the actuator will cease motion In the event a force is applied to the actuator that causes the motor current to exceed this settable value for more than 50 ms the actuator wil...

Page 22: ...ances or play in the actuator Range 0 0 mm to 300 0 mm Resolution 0 1 mm bit 0 offset 5 2 5 2 Measured current This 9 bit signal is used to inform the user of the actual current being drawn used by th...

Page 23: ...vibration being applied to the actuator 5 2 5 9 Parameter flag This 1 bit signal is used to inform the user that one of the parameter signals in the ACM is outside the allowed parameters the specific...

Page 24: ...fatal error message The actuator has encountered an uncommanded change in the stroke feedback device potentiometer The user can reset the actuator first to try and clear the error but if that does not...

Page 25: ...oad duty cycle 25 C see product label Restraining torque Nm lbf in 0 internally restrained Motor leads cross section mm2 AWG 0 75 18 Signal leads cross section mm2 AWG 0 35 22 Cable length depending o...

Page 26: ...dular Control System options XXX internal end of stroke limit switches XXP XXX analog potentiometer position output EXX Electronic Monitoring Package EXP EXX analog potentiometer position output LXX E...

Page 27: ...Thomson Thomson Electrak MD Actuator Installation Manual 2020 02 27...

Page 28: ...llo 95 97 20834 Nova Milanese MB Phone 39 0362 366406 Fax 39 0362 276790 E mail sales italy thomsonlinear com Spain Thomson E mail sales esm thomsonlinear com Sweden Thomson Estridsv g 10 29109 Kristi...