9. Port Protocols GVG-200 Emulation
Diamond digital
149
9.5.6
AUTO TRANSITION RATE COMMAND (CC, CD)
The command byte is followed by three ”rate bytes” which contain the auto transi-
tion time in BCD. If the first rate byte comes with the highest bit set, the auto transi-
tion is immediately started after setting the desired rate. If this bit is zero, only the
rate is set. Because only three bytes are used, the range for the rate can be 0-999
frames. The hundreds are transmitted in the first byte, followed by the tens and
units digits.
9.5.7
TRANSITION KEY SELECT (FB)
This command acts in the Diamond digital in the same way as the AUTO (transition)
key on the control panel: an auto transition is started on the switcher.
1BH:
Auto Transition MES
18H:
Auto Transition DSK
1FH: Auto
Transition
FTB
9.5.8
ALL STOP COMMAND (F2)
Stops ongoing auto transitions.
Stops ongoing EXTRA dissolves and running EXTRA sequences.