MAINTAIN
Sustaining the set temperature (if the burner's working mode is in the mode
of continuous work)
BURNING OFF
Putting off the burner. Active in the “STOP” mode or in the temporal working
mode of the burner.
STANDBY
Standby of the burner for the decline of the temperature of a hysteresis (if
the burner's working mode is in the temporal mode).
8.
Parameters
To move round the menu and to set particular parameters there are four buttons placed on the
driver's panel:
“MODE/ ”
,
“MENU/OK”
,
“+”
,
“-”
. The parameters chosen by the user are
divided into four groups: (A)
“CH FURNACE SETTINGS”
, (B)
“WUW BUFFER SETTINGS”
,
(C)
“BURNER SETTINGS”
, (D)
“DRIVER SETTINGS”
. The division of particular parameters
in groups is shown in the
“Settings table”.
CH FURNACE SETTINGS (A)
FUNCTION
NO.
FUNCTION
NAME
SETTING
UNIT
SETTING
RANGE
MANUFACTURER
SETTING
1
HEATING WATER
TEMPERATURE
ºC
35 - 85
65*
2
CH PUMP ACTIVATION
TEMPERATURE
ºC
20 - 60
35*
3
CH FURNACE
HYSTERESIS
ºC
1 - 20
5*
4
THERMOSTAT 2
TEMPERATURE
ºC
10 – 90
Off*
5
FURNACE
MODE
---
Winter/Summer
Winter*
WUW BUFFER SETTINGS (B)
FUNCTION
NO.
FUNCTION
NAME
SETTING
UNIT
SETTING
RANGE
MANUFACTURER
SETTING
1
WUW BUFFER
TEMPERATUR
ºC
20 - 80
40*
2
WUW SURPLUS
TEMPERATURE
ºC
5 - 20
10*
3
WUW
PRIORITY
---
Yes/No
No*