9.
Manufacturer menu
9.1.
Activation of Manufacturer's menu
In order to activate the manufacturer's settings menu, go to the settings menu of the
driver "DRIVER SETTINGS" and sub-menu "ENABLE SERVICE MODE" and with the help
of buttons "MENU/OK" and "+" or "-" choose the code 112. Then, press "MODE/ " and
leave the sub-menu, go to the menu "MANUFACTURER SETTINGS"
* CAUTION!!
Manufacturer's settings are exclusively the suggestion. All of the values depend on the kind of
solid fuel, the sysytem, the user's requirements, etc.
The producer of the burner reserves the changes of the ranges of settings in next versions of
the driver.
9.2.
Description of manufacturer's settings
FEEDER FILLING TIME
In this menu the manufacturer sets the time of the feeder's filling. The time is the protection
from filling up of the burner. This time depends on the angle of arrival of the large feeder. The
parameter is set in the bracket of 5 to 20 minutes.
Manufacturer Advice:
10-12min
PELLETS IGNITION TIME
In this menu the manufacturer sets the time of the pellet's ignition. After the lapse of time, the
ignition cycle restarts. The cycle is repeated once again. Unsuccessful trials of ignition are seen
on the screen as a message:
no pellets
. The cause of this condition may be also a broken or
dirty flame's sensor. The time of ignition is set in the bracket of 1 to 15 minutes.
Manufacturer Advice:
6-7min
FAN POWER (IGNITION)
In this parameter the producer sets the power of the fan during the pellet's ignition. The fan's
power is set in the bracket of 5 to 50%.
If chimney's draught is over -15Pa, then the parameter stays at 10%
If chimney's draught is from 0 to -15Pa, then the parameter must change to 15-20%.
Manufacturer Advice:
15-20%