1
In the
Ignition MODE
activates the feeder for the time specified on the
parameter “Filling Feeder Time”
2
Go to the previous menu or parameter
Decreases the value of a parameter
1
In the
Ignition MODE
activates the ignition procedure
2
Go to the menu or parameter
Increases the value of a parameter του καυστήρα.
6.3.
Technical characteristics of the controller
Sensors:
KTY-210
Measurement range:
0 – 120°C
Measurement resolution:
0.1
o
C
Time of measurement:
1 s
Data reading:
LCD screen 2x20 signs
Steering outputs:
Igniter: ~230V 2A (0.8A)
Feeder: ~230V 2A (0.8A)
Burner's fan: ~230V 2A (0.8A)
CH pump: ~230V 2A (0.8A)
WUW pump: ~230V 2A (0.8A)
Cleaning System
Protection:
Electric Fuse 4A
Inputs:
Room thermostat: Open contact
Temperature sensors: KTY-210 Temperature STB (95°C)
Visual signaling:
LED diodes Signalling the status of outputs
LCD screen Messages, measurements, settings
Power supply:
~230 V 50Hz 2VA
7.
Operation functions
After switching the burner on, it is appeared on the LCD screen the program's logo defining the
type of the driver and the version of the current software
While activating, the burner carries out a test of the connected sensors. In case of one lacking,
on the screen appears an appropriate message (---). The work of the burner without a heating
water temperature sensor (CH) is blocked and an emergency mode is activated (CH pump is still
on).