background image

For more information, visit www.fmiproducts.com

VENTED GAS LOG APPLIANCE

OWNER’S OPERATION AND INSTALLATION MANUAL

WHEN USED AS AN OUTDOOR APPLIANCE

WHEN USED AS INDOOR VENTED APPLIANCE

REMOTE-READy LOG SET AND BURNER SySTEM 

MODELS 

MF42ONE, MF42OPE, MF48ONE, MF48OPE

MF42 MODELS MAY BE USED WITH LMF42-SC LOGS ONLY 
MF48 MODELS MAY BE USED WITH LMF48-SC LOGS ONLY

 

WARNING: If the information in this manual is not followed exactly, a fire or explosion 

may result causing property damage, personal injury or loss of life.

—  Do not store or use gasoline or other  flammable vapors and liquids in the  vicinity of 

this or any other appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your building.
•  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s 

instructions.

•  If you cannot reach your gas supplier, call the fire department.

—  Installation and service must be performed by a qualified installer, service agency or the 

gas supplier.

INSTALLER: Leave this manual with the appliance.

 

CONSUMER: Retain this manual for future reference.

 

WARNING: Improper installation, adjustment, alteration, service or maintenance can 

cause injury or property damage. Read the installation, operating and maintenance instruc

-

tions thoroughly before installing or servicing this equipment.

 

WARNING: No not store gasoline or other flamable vapors and liquids in the vicinity of 

this or any other appliance. An LP-cylinder not connected for use shall not be stored in the 

vicinity of this or any other appliance.

 

WARNING: For Outdoor Use Only.

PFS

®

US

DANGER

CARBON MONOXIDE 

WARNING

This appliance can pro

-

• 

duce carbon monoxide 

which has no odor.

Using it in an enclosed 

• 

space can kill you.

Never use this appliance 

• 

in  an  enclosed  space 

such as a camper, tent, 

car or home.

       DANGER

IF YOU SMELL GAS:

Shut off gas to appliance.

1. 

Extinguish any open flame.

2. 

If  odor  continues,  keep  away  from  the 

3. 

appliance and immediately call your gas 

supplier or fire department. 

Summary of Contents for MF42ONE

Page 1: ... the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instruc tions thoroug...

Page 2: ...mote accessory keep selector switch in the OFF position to prevent children from turning on burners with remote WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operation al procedures For assistance or additional information consult a qualified installer ser vice agency or the gas supp...

Page 3: ...Maintenance page 16 8 Before using furniture polish wax carpet cleaner or similar products turn appliance off If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls and furniture 9 Do not use this appliance as a wood burning appliance Use only the logs provided with the appliance Do not burn solid fuels in this appliance 10 Do not run appl...

Page 4: ...rson must install appliance Follow all local codes NOTICE State or local codes may only allow operationofthisapplianceinaventedconfigu ration Check your state or local codes WARNING Makesuretheselectorswitchisin the OFF position before installing appliance WARNING Never install the appliance in a recreational vehicle wherecurtains furniture clothingorotherflam mable objects are less than 36 from f...

Page 5: ...e hood accessory 24 and 30 Models Only See Figure 3 for minimum clearances If Using Mantel You must have noncombustible material s above the fireplace opening Noncombustible materials such as slate marble tile etc must be at least 1 2 thick With sheet metal you must have noncombustible material behind it Noncombus tible material must extend at least 8 up for all models If noncombustible material i...

Page 6: ...Fireplace Clearances Above Combustible Flooring Installation Continued Determining Minimum Mantel Clearance When Using a Hood If minimum clearances in Figure 4 are not met you must have a hood When using a hood there are still certain minimum mantel clearances required Follow minimum clearances shown in Figure 5 when using hood INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note When used ...

Page 7: ...n for clarity 2 1 8 NPT Plugged Tapping MAIN IN OUT PILOT ADJ PILOT Pilot Adjustment Inlet Pressure Tap Outlet Pressure Tap Gas Shutoff Valve Flexible Gas Line Do NOT Kink 1 2 NPT Incoming Gas Line Set Screw Installation Items Needed hardware package provided with appliance approved flexible gas hose and fittings provided if allowed by local codes sealant resistant to propane LP gas not provided e...

Page 8: ...s This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged appliance valves WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas Figure 11 External Regulator With Vent Pointing Down Propane LP Supply Tank External Regulator with Vent Pointing Down Installation Continued Figure 10 Attaching Base to Fireplace Floor Model Shown May Va...

Page 9: ...imum inlet pressure for purpose of input adjustment Figure 12 Gas Connection Pipe Cap Tee Nipple Joint Gas Control 3 Minimum Sediment Trap Equipment Shutoff Valve With 1 8 NPT Tap Approved Flexible Gas Hose if allowed by local codes Propane LP From External Regulator 11 W C to 14 W C Pressure Natural From Gas Meter 5 W C to 10 5 W C Pressure 2 Cap off open end of gas pipe where equipment shutoff v...

Page 10: ...nce see To Turn Off Gas to Appliance page 14 Figure 16 MF Series Burner System Log Compatibility Chart INSTALLING LOGS and Lava Rock WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury CAUTION Afterinstallationandperiodically thereafter checktoensurethatnoflam...

Page 11: ...urner Tube Square Grate Find the back left log LMF42 SC D 018 or LMF48 SC 2 D026 See Figures 18 18A and 18B Figure 18A shows how the log must fit against the end of the burner Figure 18B shows how the notch in log fits against the vertical portion of the burner tube Place this log on the base assembly by inserting it from the left side as shown in Figure 18 You will need to twist the log slightly ...

Page 12: ...20 Place this log on the base as shown in fig ures Vertical Portion of Burner Tube Find the front left log LMF42 SC D017 or LMF48 SC 3 D025 See Figures 19 19A and 19B The log has a rect angular stand off on the bottom that fits against the lip on the black metal base as shown in figure 19A The bottom of this log has a slot that fits over the second bar on the grate as shown in Figure 19B Place the...

Page 13: ... D 021 or D028 Square Peg Square Grate Log Notch Figure 23 Installing Front Top Log Front Top Log D 024 Rectangular Peg Right Split Crossover Log D 022 Middle Split Log Figure 21A Installing Middle Split Log Rear Top Side View Figure 22 Installing Right Split Crossover Log Log Notch Burner Tube Find the front top log D 024 See Figure 23 The left end 7 of this log has a square hole that fits over a...

Page 14: ...ight any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions C Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has be...

Page 15: ...he module s internal receiver accepts the transmitter code there will be a series of confirming beeps The remote system is ready for use Remote Off Switch ADJ S Pilot Connection I Pilot Connection AF 4000 MOD Module Rt Side Figure 26 Gas Module Right Side AF 4000 MOD Module Lt Side AUX Connection Learn Button Figure 27 Gas Module Left Side Inspecting Burners Check burner flame patterns often IGNIT...

Page 16: ...holder for dust and dirt see Figure 31 3 Blow air through the ports slots and holes in the burner 4 Check injector holder located at end of burner tube again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner repeat st...

Page 17: ...m Orange Orange Orange Red Brown Black Solenoid White Brown Brown Green Ignitor Pilot I S AUX AF 5000MOD AF 4000 AF 4000B P Control Module Black Black Optional D Red SWI SWI GND Black Red HI LO Main Black These wires are not used on this application ...

Page 18: ... s clogged 8 Wire disconnected from gas con trol REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor 4 Replace ignitor 5 Adjust ignitor wires as shown in Figure 28 on page 15 Replace ignitor assembly if repositioning does not correct the problem 6 Replace ignitor 7 Install new alkaline battery in remote control and batter...

Page 19: ...l air is re moved from line Have gas line checked by local natural or pro pane LP gas company 2 Observe minimum installation clearances see pages 9 through 11 3 Clean burner see Cleaning and Maintenance page 16 or replace burner orifice s 1 Turn appliance off when using fur niture polish wax carpet cleaners or similar products 1 Replace batteries in battey pack and in hand held remote 1 This is no...

Page 20: ...t hairspray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Low fuel supply propane LP only 3 Gas leak See Warning state ment at top of page 1 Low line pressure 1 Gas leak See Warning state ment at top of page 2 Control valve or gas control de fective 1 Gas leak See Warning state ment at top of page REMEDY 1 Open window to ventilate room Stop using odor causing products whi...

Page 21: ...ed on the back page of this manual FIREPLACE HOOD Black GA6050 Antique Brass GA6053 For all models Helps deflect heat away from mantel or wall above fireplace Fits openings 28 to 48 wide DAMPER CLAMP GA6080 For all models Permanently opens chimney flue damper for vented operation LAVA ROCK GA6060 For all models Order when additional rock is desired MAGNIFLAME ACCESORY LOG KIT LAMF MAGNIFLAME ember...

Page 22: ...www fmiproducts com 125636 01A 22 Parts Remote Ready Control Models MF42oNe MF42oPe MF48oNe MF48oPe 1 2 4 5 6 7 8 9 10 11 12 13 15 16 18 19 20 21 23 24 25 26 22 17 14 8 3 ...

Page 23: ...ytech 1 125647 02 Srew 00 Min Rate Skytech 1 15 125607 01 Cap 3 8 Compression 1 16 112823 01 T Fitting Brass 3 8 Tube x 3 8 NPT 1 17 125603 01 Grate MF42 Stainless Steel 1 125603 02 Grate MF48 Stainless Steel 1 18 111817 01 Flextube Dormont 3 8 X 15 1 19 111824 01 Brass Compression Cap Slv 3 8 1 20 124933 01 Orifice Holder 90 Degree Elbow 1 21 099056 49 Orifice 128 1 099056 31 Orifice 070 1 22 116...

Page 24: ...te the set size KEY NO DESCRIPTION QTY Part Number Log ID Number Part Number Log ID Number 1 125573 01 D 019 125591 01 D 027 Log Front Right 1 2 125573 02 D 018 125591 02 D 026 Log Back Left 1 3 125573 03 D 017 125591 03 D 025 Log Front Left 1 4 125573 04 D 020 125573 04 D 020 Log Charred 1 5 125573 05 D 021 125591 04 D 028 Log Middle Split 1 6 125573 06 D 022 125573 06 D 022 Log Right Split Cross...

Page 25: ...tioning purchase date Usually we will ask you to return the part to the factory Service Hints When Gas Pressure Is Too Low burners will have delayed ignition appliance will not produce specified output propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local propane LP or natural gas supplier Technical Service You may have further questions about installa...

Page 26: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Page 27: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Page 28: ...r FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material laborandincidentalcostsassociatedwithwarrantyrepairs unlessexpresslycovered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded from this warranty are pr...

Reviews: