background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

IG0287#02 

18.05.2021 

 

 

 

INSTALLATION and U

SER’S MANUAL 

KL21 Rio 

G30/G31 (Propane-Butane/Propane) 

 

 

 

  

H1 

H2 

L1 

L2 

[mm] 

 414 

310  

100  

 698 

 591 

53 

 300 

L2

L1

L2

D

H2

H1

L

H

Summary of Contents for KL21 Rio

Page 1: ...right Planika Sp z o o www planikafires com IG0287 02 18 05 2021 1 INSTALLATION and USER S MANUAL KL21 Rio G30 G31 Propane Butane Propane H H1 H2 L L1 L2 D mm 414 310 100 698 591 53 300 L2 L1 L2 D H2 H1 L H ...

Page 2: ...nly LPG version 6 3 5 Installation of the gas linkage 7 3 5 1 Connection and replacement of the gas cylinder LPG version 7 3 5 3 Regulator replacement 10 4 OPERATING INSTRUCTIONS 11 4 1 General Notes 11 4 2 Start up of the device 11 4 3 Regulation of the flame size 12 4 4 Device shutdown 12 5 TESTING 13 5 1 Checking for gas leaks 13 5 2 Checking the flame appearance 13 6 MAINTENANCE AND UPKEEP 14 ...

Page 3: ...r any glowing coal fragments on the burner or in the combustion chamber A CO2 or a powder fire extinguisher needs to be placed near the device During the first ignition The Rio fireplace needs to be burnt on maximum level for a few hours in order for the elements to acquire correct temperature and for the remains of paint lacquer and lubricant to evaporate Do not move the device while it s working...

Page 4: ... with the use of a cleaning liquid and water If bubbles form on the surface that means that a there s an existing leak Always use a pressure regulator between the gas bottle and the device Replace the pressure regulator every 5 years The allowed pressures are 30mbar 37mbar recommended 50 mbar Use only regulators complying with the European EN16129 Norm Use only approved and certified gas connectio...

Page 5: ...e appliance and pull out the glass shield wrapped in cardboard from the inside of the Rio Check the completeness of the elements with the contents list Make sure that the device nor its elements weren t damaged during the transportation if they were notify the supplier Place Rio on a flat paved surface outside of the building preferably on the place of final installation Leave sufficient space on ...

Page 6: ...tion slot above the top of the bottle of an area min 1 100 of the area of the base of the housing and a lower ventilation slot of an area min 1 50 of the area of the base of the housing The dimensions of the housing may vary to accommodate different types and dimensions of the gas bottles however they also have to be sufficient for hassle free installation of the gas bottle Carefully remove cardbo...

Page 7: ... Rio fireplace can use metal or steel bottles or composite bottles filled with propane butane gas or propane gas This device features a twist on regulator with current pressure of 37mbar It can be replaced into a regulator with a quick release with pressure regulator of 37 mbar WARNING NEVER use an unstable gas connection or a regulator for other gas pressure Gas cylinders have two types of connec...

Page 8: ...he gas bottle connectors to be fastened too tightly 3 Place the quick release regulator on the valve and press it down hard If the switch is correctly turned off you will hear a characteristic click 5 When the gas flow is required turn the valve of the bottle counter clockwise 4 To let the gas flow in turn the switch into the ON position or into the flame image Place the gas bottle in a correct di...

Page 9: ...unmount the regulator or connecting nut when the bottle valve is open 4 TAKE OFF the regulator or the connecting nut with the use of a wrench or a connecting knob 3 Take off the quick release regulator by pressing the switch horizontally and simultaneously pulling the whole regulator upwards 5 REPLACE the linkage closer or cap on the empty or partially full bottle if it s not being used 4 REPLACE ...

Page 10: ...on above Twist on connection Quick release 4 Cut off attached pressure reducer or go to step 4 1 if you have pressure reducer with clamp connection 5 Replace the regulator to new one with clamp connection by attaching new linkage on the stub of regulator 6 Move the clamp into the stub 7 Tighten the clamp with screwdriver philips or a flat wrench WARNING In the event of visible damage on the clamp ...

Page 11: ... to the knob is placed elective ignition button powered by AAA battery The control panel is placed on one of the shorter sides of the base of the fireplace Fig 5 Control knob 4 2 Start up of the device Make sure that the knob is placed in OFF position all the way clockwise Fig 6 Off position Open the valve on gas cylinder Press the knob and while still pressing turn it counter clockwise from posit...

Page 12: ... the connections Try again in 10 minutes If the installed gas bottle is new or the fireplace has not been used for a longer pe Riod the first thing that needs to be done is to release air from the gas linkage In this case conducting a few attempts will be needed until the flame is ignited 4 3 Regulation of the flame size When the flame is burning the desired height of the flame may be adjusted and...

Page 13: ... if all connections are airtight To do that apply all connections with soapy water or water with another foamy substance or with a professional spray for leak detection If air bubbles are present that means the connection has a leak Remove the leaks in the identified spaces Check for leaks once again After the inspection dry the inspected connections The device may only be used again after all lea...

Page 14: ...the gas supplier PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION SMELL OF GAS CLOSE THE VALVE ON THE GAS CYLINDER IMMEDIATELY DO NOT USE THE DEVICE UNTIL LEAKS HAVE BEEN REMOVED Leak detected at cylinder regulator or other connection 1 A loose regulator linkage 2 Leak in the gas linkage in the regulator or on the gas knobs 1 Tighten and test it 2 Report this issue to service Burner does not ignite 1 The ...

Page 15: ...Category I3P I3B P I3 Reference gas G31 G30 G30 G31 Inlet pressure mbar 30 37 50 30 37 50 28 30 37 Injector diamater mm 1 4 1 4 1 4 Gas consumption kg h 0 5 0 55 0 65 0 5 0 55 0 65 0 5 0 55 Nominal Heat Input Hi kW 6 4 7 8 3 6 4 7 8 9 1 7 4 7 4 Nominal Heat Input Hs kW 7 7 7 9 0 7 8 5 10 8 8 Safety device Thermocouple Gas control valve BS190 Flexible hose 4 m Ø9mm ...

Page 16: ...ion and User s Manuals I hereby declare that having read the User s Manual and the Guarantee Conditions Date and legible signature of the Buyer INSTALLER Name Address Tel fax Date of commissioning I hereby declare that the gas fireplace installed by my Company has been installed in accordance with the applicable building regulations and in accordance with the guidelines contained in the Installati...

Reviews: