pg. 17
ADJUSTING THE COMBUSTION WITH THE INSERT IN MANUAL MODE
The thermal value is adjusted by pressing button (1) on the handheld radio control (see para. 5.9.2). Act on this command to adjust the
quantity of pellets fed to the firebox. Maximum combustion power is achieved when all 5 bars are lit.
Caution: The fan starts as soon as the heater body exceeds 42°C. The fan setting is expressed visually by means of 6 different
positions represented by 6 bars: press button (2) repeatedly to regulate it.
6.3 FIL
6.3 FIL
6.3 FIL
6.3 FIL
6.3 FILTER
TER
TER
TER
TER
This practical device prevents the circulation of dust which is always present in
household environments. The filter is installed at the back of the heater (see figure on
the right). Clean frequently to ensure the maximum availability of hot air when the
heater is operating (wash the filter with cold water then dry thoroughly every 5
days).
6A
6A
6A
6A
6A
USE OF
USE OF
USE OF
USE OF
USE OF THE "ECO
THE "ECO
THE "ECO
THE "ECO
THE "ECOTHERM 3001
THERM 3001
THERM 3001
THERM 3001
THERM 3001 THERMOCOMFOR
THERMOCOMFOR
THERMOCOMFOR
THERMOCOMFOR
THERMOCOMFORT" HEA
T" HEA
T" HEA
T" HEA
T" HEATER
TER
TER
TER
TER
6A.1
6A.1
6A.1
6A.1
6A.1
SWIT
SWIT
SWIT
SWIT
SWITCHING ON
CHING ON
CHING ON
CHING ON
CHING ON THE HEA
THE HEA
THE HEA
THE HEA
THE HEATER
TER
TER
TER
TER
Before using the appliance check that all the movable parts are in place; also remove any labels and stickers from the glass to avoid having
permanent traces remain on the surfaces.
Turn the switch installed on the back of the heater to position "1" (= ON). Press button (1) to start the start up phase. When key (1) is
repeatedly pressed, the desired combustion level can be set and it will be active at the end of the ignition stage.
The electrical heater will start to overheat and after a few minutes the first lot of pellets will start dropping into the brazier. This occurs
because the screw feeder has to fill up because it is completely empty. The first time the heater is started up the start up phase will have to
be carried out twice for this very reason.
CAUTION : The start up phase (word Start appearing on the display) takes 20 minutes during which the heater ignores any
commands transmitted to it. After this time has elapsed the word On appears on the display. The fan starts as soon as the heater
body exceeds 42°C. During the work stage it is then possible to adjust combustion and the ventilation: Combustion is adjusted by 5
leds (through key (1)) , while the ventilation adjustment is distributed over 6 levels shown by the leds that turn on in succession
(through key (2)).
To turn the heater on it is necessary for the inscription OFF to be present on the display; if it is not present, the key (6) must be
repeatedly pressed until the inscription OFF appears.
The heating capacity is adjusted by pressing key (1) or on the remote control provided . Act on this command to adjust the quantity of pellets
fed to the firebox. Maximum combustion power is achieved when all 5 leds are lit.
Caution: The fan starts as soon as the heater body exceeds 42°C. The fan setting is expressed visually by means of 6 different
positions represented by 6 bars: press button (2) repeatedly to regulate it.
A slight vibration of the heater is quite normal when it is running.
6A.2
6A.2
6A.2
6A.2
6A.2
ADJUSTING
ADJUSTING
ADJUSTING
ADJUSTING
ADJUSTING THE HEA
THE HEA
THE HEA
THE HEA
THE HEATER'S COMB
TER'S COMB
TER'S COMB
TER'S COMB
TER'S COMBUSTION
USTION
USTION
USTION
USTION AND
AND
AND
AND
AND VENTILA
VENTILA
VENTILA
VENTILA
VENTILATION
TION
TION
TION
TION
A practical infrared remote control is supplied with the heater: press the left button to adjust the ventilation level, press the right button to
adjust the combustion level. If the heater is supplied with a white radio control (optional) the infrared control only works when the MANUAL
setting is set on the white handheld radio control.
6A.3
6A.3
6A.3
6A.3
6A.3
INFRARED CONTROL
INFRARED CONTROL
INFRARED CONTROL
INFRARED CONTROL
INFRARED CONTROL
INTRODUCTION
The handheld radio control is the device that allows you to control Ecotherm in order to optimise consumption and its functions. Keep in mind
that radio wave transmissions can be affected by the surrounding environment: the presence of thick walls can reduce the transmission that
normally extends to 6-7 metres.
6A.4
6A.4
6A.4
6A.4
6A.4
OPERA
OPERA
OPERA
OPERA
OPERATION OF
TION OF
TION OF
TION OF
TION OF THE
THE
THE
THE
THE WHITE HANDHELD RADIO CONTR
WHITE HANDHELD RADIO CONTR
WHITE HANDHELD RADIO CONTR
WHITE HANDHELD RADIO CONTR
WHITE HANDHELD RADIO CONTROL (OPTION
OL (OPTION
OL (OPTION
OL (OPTION
OL (OPTIONAL)
AL)
AL)
AL)
AL)