pg. 18
3
4
2
1
7
6
5
8
9
10
11
13
12
6A.4.1
6A.4.1
6A.4.1
6A.4.1
6A.4.1 Indicators of the handheld radio control
Indicators of the handheld radio control
Indicators of the handheld radio control
Indicators of the handheld radio control
Indicators of the handheld radio control
(1) Flame adjustment button
(2) Ventilation adjustment button
(3) (4) Auxiliary keys
(5) “Room temperature detected by the radio control's sensor indicator"
(6) "Ventilation" indicator
(7) "Combustion" indicator
(8) “Room temperature setting" indicator : this is the room temperature that you wish
to reach by means of buttons 3 and 4.
(9) Area of the display where the operating program is displayed
(10) Battery charge level
(11) Switch 0-1 radio control power
(12) Battery charger connection
(13) Code selector and Batteries compartment cover
The Thermocomfort radio control can be used with 4 different operating programs:
- Manual (MANUAL appears in area (9) of the display)
- Automatic 5 (AUTO 5 appears in area (9) of the display)
- Automatic 3 (AUTO 3 appears in area (9) of the display)
- Economy (ECONOMY appears in area (9) of the display)
To change the operating program turn the switch (11) to "1". Press and hold down button (3) until the set program begins to blink on the
display (9). Now release button (3) and press button (3) and/or (4) repeatedly until you select the desired operating program.
CAUTION: to guarantee optimal data transmission it is advisable to always place the radio control in its support in a vertical
position.
The following operations must be carried out the first time the heater is started up :
- Turn the switch (11) to ON (see drawing below)
- Connect the radio control by means of the battery charger supplied to the power line, ( it must be recharged for
at least 5 days); as the rechargeable batteries could be partially or completely flat). Leave the radio control
connected at all times, by means of the battery charger, to the power supply line. The heater must be
energised and the switch turned to position "1".
At the end of the winter season it is mandatory to switch off the radio control completely, by means of the
switch situated inside the battery compartment, in order to preserve the life of the batteries. The batteries are
guaranteed for 6 months. When the batteries are exhausted dispose of them safely. It is normal for the tempera-
ture sensor to detect temperatures which are slightly different to the real ones: variations caused by the
environment in which the radio control is positioned.
MANUAL program
In the MANUAL program the room temperature thermostat is disabled. Press button (1) and the flame symbol begins to blink. Press button (3)
to decrease the combustion level, viceversa press button (4) to increase the combustion level. The combustion level changes with each
press of buttons (3) and (4).
Press button (2) and the ventilation symbol blinks. Press button (3) and the combustion level decreases,
vice versa press button (4) to increase the combustion level. The ventilation level changes with each press of buttons (3) and (4) . Caution:
it is possible that, due to radio interference, the commands sent to the heater will not be implemented.
With this program you can also use the infrared control supplied.
It is normal that in the manual cycle the ventilation is often set at the
maximum speed in order to cool the heater body more effectively.
AUTO 5 program
In program AUTO 5 the room temperature thermostat is enabled. The remote control adjusts the ventilation and combustion automatically in
relation to the target room temperature set in display area (8). You can vary the desired room temperature by simply pressing button (3) and/
or (4) (variation indicated in area (8)). The remote control will set the maximum combustion and ventilation levels and modulate them both as
the room temperature (5) approaches the target temperature (8). When the target temperature (8) in the room (5) is reached, the combustion
level will stabilise on a bar as will the ventilation level. Caution: it is possible that, due to radio interference, the commands sent to the heater
will not be implemented. You cannot use the infrared control with this program.
AUTO 3 program
In program AUTO 3 the room temperature thermostat is enabled . The remote control adjusts the ventilation and combustion automatically in
relation to the target room temperature set in display area (8). You can vary the desired room temperature by simply pressing button (3) and/
or (4) (variation indicated in area (8)). The remote control will set the combustion power at level 3 and the ventilation at level 4 and modulate
them both as the room temperature (5) approaches the target temperature (8). When the target temperature (8) in the room (5) is reached,
the combustion level will stabilise on a bar as will the ventilation level. Caution: it is possible that, due to radio interference, the commands
sent to the heater will not be implemented. You cannot use the infrared control with this program.