pg. 8
5
5
5
5
5
DESCRIPTION OF ECOTHERM 3001 CONTROLS
DESCRIPTION OF ECOTHERM 3001 CONTROLS
DESCRIPTION OF ECOTHERM 3001 CONTROLS
DESCRIPTION OF ECOTHERM 3001 CONTROLS
DESCRIPTION OF ECOTHERM 3001 CONTROLS
5.1
5.1
5.1
5.1
5.1
DESCRIPTION OF GREY HANDHELD RADIO CONTR
DESCRIPTION OF GREY HANDHELD RADIO CONTR
DESCRIPTION OF GREY HANDHELD RADIO CONTR
DESCRIPTION OF GREY HANDHELD RADIO CONTR
DESCRIPTION OF GREY HANDHELD RADIO CONTROL
OL
OL
OL
OL AND HEA
AND HEA
AND HEA
AND HEA
AND HEATER REAR P
TER REAR P
TER REAR P
TER REAR P
TER REAR PANEL
ANEL
ANEL
ANEL
ANEL
INTRODUCTION
The handheld radio control is the control instrument for your heater that will permit you to manage Ecotherm and its functions. The radio
control is a user-friendly way of interacting with the main heater settings and, when required, of accessing the various other control
commands. In both cases the Manufacturer recommends you read the following pages carefully so that you will know how to make the best
use of your heater. Keep in mind that radio wave transmissions can be affected by the surrounding environment: the presence of thick walls
can reduce the transmission that normally extends to 6-7 metres.
CAUTION: to guarantee optimal data transmission it is advisable to always place the radio control in its support in a vertical
position.
The following operations must be carried out the first time the heater is started up :
- Turn the switch inside the battery compartment to ON (see drawing below)
- Connect the radio control by means of the battery charger supplied to the power line, ( it must be recharged for
at least 5 days: see para. 8.3), as the rechargeable batteries could be partially or completely flat). Leave the radio
control connected at all times, by means of the battery charger, to the power supply line. The heater must be
energised and the switch turned to position "1". At the end of the winter season it is mandatory to switch off the
radio control completely, by means of the switch situated inside the battery compartment, in order to preserve
the life of the batteries.
The batteries are guaranteed for 6 months. When the batteries are exhausted dispose of
them safely. It is normal for the temperature sensor to detect temperatures which are slightly different to the
real ones: variations caused by the environment in which the radio control is positioned.
(1) Insert on/off and flame adjustment button When you press this button the appliance (10) switches to ON/ RUNNING/ OFF. Press
repeatedly to activate up to 5 bars (7) and the AUTO indicator is activated (8 automatic) .
(2) Ventilation setting button Press this button to set the desired level of ventilation: up to a maximum of 6 speeds are available, indicated by
the lighting of the corresponding bar (6).
5.1.2
ROOM TEMPERATURE THERMOSTAT OPERATION
When the AUTO function is activated the temperature value detected by the temperature sensor (5) installed in the radio control is updated at
regular intervals.During the start up phase the temperature value is not updated. The temperature value transmitted to the heater does not change
the instant there is a sudden change in the room temperature but it is updated regularly through the DATA ANALYSIS function. It is normal for the
temperature sensor to detect temperatures which are slightly different to the real ones: these variations are caused by the environment in which
the radio control is positioned and by the prolonged use of the display.
On
On
On
On
1
2
2
ON
O N
O N
5.1.1 HANDHELD RADIO CONTROL
A description of the buttons and indicators on the radio control follows:
The radio control consists of a plastic shell on which is installed a backlit LCD display with control buttons, interface card and
rechargeable batteries: the backlighting switches off temporarily during use in order to reduce energy consumption which consequently
extends the duration of the charge. There are two main control pushbuttons marked with the ventilation symbol (2) and the symbol of
the flame (1). The flame button (1) sets the heater power, there are a possible 5 power levels displayed by the 5 bars progressively
coming on in sequence (7). You can select the AUTOMATIC mode displayed by the text word AUTO (see paragraph 5.9 ). The shutdown
cycle appears on the display when all the power bars are off. The fan button (2) controls the ventilation of the heater. The heater
activates when the temperature exceeds 42 °C. The ventilation can be set up to 6 speed levels: when the heater is on the ventilation
cannot be switched off.
Therefore, in brief, the two buttons function as follows: