Service settings manual
38
Table with description of parameters
:
Para-
meter
Function
Parameter description
Setting range
Default
value
F1.1 OUTPUT PROGRAM-
MING
Selection of output for programming.
0- NO 1- R1
2- R2 3- R3
0
F1.2 DEPENDENCE TO
OTHER OUTPUTS
Define dependence of programmed output to other
controller's outputs.
&- selected relay has to be switched-on for program-
med output to be able to switch- on
&!- selected relay has to be switched-off for program-
med output to be able to switch- on
I- programmed output will switch-on always when
selected relay is switched-on
I!- programmed output will always switch- on when the
selected relay is switched-off
0- NO
1- &
2- &!
3- I
4- I!
0
F1.3 DEPENDENT
OUTPUT
Selection of output on which depends operation of
programmed output.
1- R1
2- R2
3- R3
2
F1.4 TIME PROGRAM
FOR OUTPUT
Selection of required time program for programmed
output.
0- NO
1- P1
2- P2
3- P3
4- P4
5- SEL. PROG. TIMER
0
F1.5 THERMOSTATIC
OPERATION OF
OUTPUT
Selection if programmed output operates as a thermo-
stat.
0- NO
1- YES
2- YES, INVERTED
3- YES, AUX. SOURCE
4- YES, CASC. SOUR-
CE
0
F1.6 TYPE OF AUXILIARY
HEAT SOURCE
Selection of type of heating source.
1- BURNER
2- EL. HEATER
3- HEAT PUMP
1
F1.7 SENSOR FOR THER-
MOSTATIC OPERA-
TION
Selection of sensor for thermostatic operation.
1- T1 2- T2
3- T3 4- T4
5- T5 6- T6
4
F1.8 THERMOSTAT
HYSTERESIS
Hysteresis for thermostatic operation. Switch ON at
T
required
, Switch OFF at T
required
+ hysteresis.
1 ÷ 30 K
4
F1.9 AUXILIARY HEAT
SOURCE - DELAYED
ACTIVATION
Selection if auxiliary heat source should activate imme-
diately or with delay if the collectors have trend and
tendency to warm the water to requested temperature.
Delay time is considered as a time in which the collec-
tors should warm the water to requested temperature.
Auxiliary heat source will activate immediately if collec-
tors don't have trend and tendency to warm the water
to requested temperature in setted delayed activation
time.
0- NO DELAY
1 ÷ 1440 min- DELAY
0
F1.10 AUXILIARY HEAT
SOURCE - STANDBY
AT MIN. TEMPERA-
TURE
Selection if auxiliary heat source should permanently
heat the water to min. temperature.
0- NO
1- YES, BY TIME PR.
2- ALWAYS
0
A1343_3
MJ/OD
06/2018
Summary of Contents for SGC36HV
Page 2: ...A1343_3 MJ OD 06 2018 ...
Page 4: ...A1343_3 MJ OD 06 2018 ...
Page 180: ...NOTES NOTIZEN POZNÁMKY 180 A1343_3 MJ OD 06 2018 ...
Page 181: ...NOTES NOTIZEN POZNÁMKY 181 A1343_3 MJ OD 06 2018 ...
Page 182: ...NOTES NOTIZEN POZNÁMKY 182 A1343_3 MJ OD 06 2018 ...
Page 183: ...A1343_3 MJ OD 06 2018 ...