E
N
G
Service settings manual
31
Table with description of parameters
:
Para-
meter
Function
Parameter description
Setting range Default
value
S1.1
HYDRAULIC SCHEME
Selection of hydraulic scheme.
depends on type
of controller
201
S1.2
CODE FOR UNLOCKING THE
SERVICE SETTINGS
This setting enables the change of code which is necessary
to unlock the service settings (S and F parameters).
WARNING! Keep new code on a safe place. Without this
code is impossible to change service settings.
0000 - 9999
0001
S1.3
TEMPERATURE SENSOR
TYPE
Selection of temperature sensors Pt1000 or KTY10.
0- PT1000
1- KTY10
0
S1.4
TEMPERATURE ROUND UP
Precision of displayed temperatures.
0- 0.1 °C
1- 0.2 °C
2- 0.5 °C
3- 1 °C
2
S1.5
PERIOD OF TEMPERAT.
LOGGING
By setting this field you define how often the measured
temperatures are saved.
1 ÷ 30 min
5
S1.6
ADVANCED DISPLAY OF
TEMPERATURES
Advanced display of temperatures displays temperatures on
main screen in double rows. First row is measured tempera-
ture; second row is required or calculated temperature.
0- NO
1- YES
0
S1.7
AUT. SHIFT OF CLOCK TO
SUMMER / WINTER TIME
With the help of a calendar, the controller carries out the
automatic clock changeover between summer and winter
time.
0- NO
1- YES
1
S1.8
ANTI-BLOCK FUNCTION
All outputs that haven’t been activated in the last week are
activated on Friday at 20:00 for 10 seconds.
0- NO
1- YES
0
S1.9
INVERTED OPERATION OF
OUTPUTS
Setting of inverted operation for outputs. Invertion of output is
possible only if operation mode of output is ON/OFF
(S3.1=0).
0- NE, 1- R1,
2- R2
3- R1, R2
4- R3
5- R1, R3
6- R2, R3
7- R1, R2, R3
…
63-R1, R2, R3,
R4, R5, R6
0
S1.10
TONES
By setting this field you define whether key pressing is
accompanied with sound signals or not.
0- OFF
1- KEYPAD
2- ERRORS
3- KEYPAD &
ERRORS
1
S1.13
SENSOR T1 CALIBRATION
Correction of displayed measured temperature for sensor T1. -5 ÷ 5 °C
0
S1.14
SENSOR T2 CALIBRATION
Correction of displayed measured temperature for sensor T2. -5 ÷ 5 °C
0
S1.15
SENSOR T3 CALIBRATION
Correction of displayed measured temperature for sensor T3. -5 ÷ 5 °C
0
S1.16
SENSOR T4 CALIBRATION
Correction of displayed measured temperature for sensor T4. -5 ÷ 5 °C
0
S1.17 SENSOR T5 CALIBRATION
Correction of displayed measured temperature for sensor T5. -5 ÷ 5 °C
0
S1.18 SENSOR T6 CALIBRATION
Correction of displayed measured temperature for sensor T6. -5 ÷ 5 °C
0
A1343_3
MJ/OD
06/2018
Summary of Contents for SGC36HV
Page 2: ...A1343_3 MJ OD 06 2018 ...
Page 4: ...A1343_3 MJ OD 06 2018 ...
Page 180: ...NOTES NOTIZEN POZNÁMKY 180 A1343_3 MJ OD 06 2018 ...
Page 181: ...NOTES NOTIZEN POZNÁMKY 181 A1343_3 MJ OD 06 2018 ...
Page 182: ...NOTES NOTIZEN POZNÁMKY 182 A1343_3 MJ OD 06 2018 ...
Page 183: ...A1343_3 MJ OD 06 2018 ...