Table with description of parameters
:
Para-
meter
Function
Setting
range
Default value
P1.1 SWITCH -ON DIFFERENCE 1
3 ÷ 30 °C depends on selected scheme *
P1.2 SWITCH -OFF DIFFERENCE 1
1 ÷ 20 °C depends on selected scheme *
P1.4 SWITCH -ON DIFFERENCE 2
3 ÷ 30 °C depends on selected scheme *
P1.5 SWITCH -OFF DIFFERENCE 2
1 ÷ 20 °C depends on selected scheme *
P1.7 SWITCH -ON DIFFERENCE 3
3 ÷ 30 °C depends on selected scheme *
P1.8 SWITCH -OFF DIFFERENCE 3
1 ÷ 20 °C depends on selected scheme *
P1.9 HYSTERESIS FOR SENSOR T1
1 ÷ 30 °C depends on selected scheme *
P1.10 HYSTERESIS FOR SENSOR T2
1 ÷ 30 °C depends on selected scheme *
P1.11 HYSTERESIS FOR SENSOR T3
1 ÷ 30 °C depends on selected scheme *
P1.12 HYSTERESIS FOR SENSOR T4
1 ÷ 30 °C depends on selected scheme *
P1.13 HYSTERESIS FOR SENSOR T5
1 ÷ 30 °C depends on selected scheme *
P1.14 HYSTERESIS FOR SENSOR T6
1 ÷ 30 °C depends on selected scheme *
P1.15 HYSTERESIS FOR SENSOR T7
1 ÷ 30 °C depends on selected scheme *
P1.16 HYSTERESIS FOR SENSOR T8
1 ÷ 30 °C depends on selected scheme *
P1.17 HYSTERESIS FOR MINIMUM TEMPERATURES
1 ÷ 10 °C depends on selected scheme *
P1.18 HYSTERESIS FOR MAXIMUM AND PROTECTION TEMPERATURES
-15 ÷ -1 °C depends on selected scheme *
Table with description of parameters
:
Para-
meter
Function
Setting range Default value
P2.1 MINIMUM TEMPERATURE OF SENSOR T1
The pump is only activated if T1 > P2.1 to avoid night time activation.
-30 ÷ 100 °C depends on selected scheme *
P2.2 MAXIMUM TEMPERATURE OF SENSOR T1
0 ÷ 200 °C
depends on selected scheme *
P2.3 MINIMUM TEMPERATURE OF SENSOR T2
-30 ÷ 100 °C depends on selected scheme *
P2.4 MAXIMUM TEMPERATURE OF SENSOR T2
0 ÷ 200 °C
depends on selected scheme *
P2.5 MINIMUM TEMPERATURE OF SENSOR T3
-30 ÷ 100 °C depends on selected scheme *
P2.6 MAXIMUM TEMPERATURE OF SENSOR T3
0 ÷ 200 °C
depends on selected scheme *
P2.7 MINIMUM TEMPERATURE OF SENSOR T4
-30 ÷ 100 °C depends on selected scheme *
P2.8 MAXIMUM TEMPERATURE OF SENSOR T4
0 ÷ 200 °C
depends on selected scheme *
P2.9 MINIMUM TEMPERATURE OF SENSOR T5
-30 ÷ 100 °C depends on selected scheme *
P2.10 MAXIMUM TEMPERATURE OF SENSOR T5
0 ÷ 200 °C
depends on selected scheme *
P2.11 MINIMUM TEMPERATURE OF SENSOR T6
-30 ÷ 100 °C depends on selected scheme *
P2.12 MAXIMUM TEMPERATURE OF SENSOR T6
0 ÷ 200 °C
depends on selected scheme *
P2.17 EMERGENCY SHUTDOWN TEMPERATURE FOR COLLECTORS
100 ÷ 280 °C depends on selected scheme *
P2.18 COLLECTOR’S FROST PROTECTION TEMPERATURE
-30 ÷ 10 °C depends on selected scheme *
* For factory settfngs see tabces on pages 168-170.
A1343_3
MJ/OD
06/2018
Summary of Contents for SGC36HV
Page 2: ...A1343_3 MJ OD 06 2018 ...
Page 4: ...A1343_3 MJ OD 06 2018 ...
Page 180: ...NOTES NOTIZEN POZNÁMKY 180 A1343_3 MJ OD 06 2018 ...
Page 181: ...NOTES NOTIZEN POZNÁMKY 181 A1343_3 MJ OD 06 2018 ...
Page 182: ...NOTES NOTIZEN POZNÁMKY 182 A1343_3 MJ OD 06 2018 ...
Page 183: ...A1343_3 MJ OD 06 2018 ...