Chapter 7: Maintenance
Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A
38
7.5
How to pack for service
When you ship the instrument for service remember to:
•
Inform about the use of hazardous materials.
•
Decontaminate the instrument beforehand.
•
Pack the instrument according to the enclosed packing instructions.
•
Use the original packaging to ensure no damage will occur to the
instrument during shipping. Any damage will incur additional labor charges.
•
Enclose a dated and signed Certificate of Decontamination (see Appendix B)
both inside and attached to the outside of the package, in which you return
your instrument (or other items).
•
Enclose the return authorization number (RGA) given by your Thermo
Fisher Scientific representative.
•
Indicate the fault after you have been in touch with your local Thermo
Fisher Scientific representative or the Thermo Fisher Scientific technical
service department.
See Section 9.1 for details on storage and transportation temperatures. See also
Section 8.3 Service request protocol.
7.6
Disposal of the instrument
Warning:
Decontaminate the instrument prior to disposal. See Section 7.4 and
Appendix B on decontamination.
Follow laboratory and country-specific procedures for biohazardous or
radioactive waste dispoal.
Warning:
The used batteries are regulated waste and must be disposed of
according to local waste regulations. The Li batteries have to be
changed by an authorized service technician only. Instructions for
changing the Li batteries are described in the service manual.
Dispose of the instrument according to the legislation stipulated by the local
authorities concerning take-back of electronic equipment and waste. The
proposals for the procedures vary by country.
WEEE symbol
Thermo Fisher Scientific has contracted with one or more
recycling/disposal companies in each EU Member State (European Country), and this
product should be disposed of or recycled through them. Further information on
Thermo Fisher Scientific’s compliance with these Directives, the recyclers in your
country, and information on Thermo Scientific products which may assist the detection
of substances subject to the RoHS Directive are available at
www.thermo.com/WEEERoHS
.
Regarding the original packaging and packing materials, use the recycling
operators known to you.
For further information, contact your local Thermo Fisher Scientific
representative.
Summary of Contents for iEMS Incubator
Page 2: ...Thermo Scientific iEMS Incubator Shaker HT User Manual Rev 2 4...
Page 3: ......
Page 4: ...Thermo Scientific iEMS Incubator Shaker HT User Manual Rev 2 4 Cat no 1506400A...
Page 61: ...Thermo Scientific iEMS Incubator Shaker HT User Manual Rev 2 4 Cat no 1506400A 58...
Page 62: ...Thermo Scientific iEMS Incubator Shaker HT User Manual Rev 2 4 Cat no 1506400A 59...
Page 63: ...Thermo Scientific iEMS Incubator Shaker HT User Manual Rev 2 4 Cat no 1506400A 60...
Page 64: ......