background image

.  Time setting knob: The knob is used

      to increase or decrease the set time 
      of the instrument.

.  Speed setting knob: The knob is used   

      to increase or decrease the set speed 
      instrument.

. Gear

 I

: When the switch is in “gear 1”, 

      the instrument power is on.

. Gear 

O

: When the switch is in “gear       

      0”, the instrument power is off.

3.3 Safety Instructions

Please read the entire instruction manual 
before operating the Digital Cel-Gro 
Tissue Culture Rotator .

WARNING DO NOT

 use the Digital 

Cel-Gro Tissue Culture Rotator  in 
a hazardous atmosphere or with 
hazardous materials for which the 
unit was not designed.  Also, the 
user should be aware that the 
protection provided by the 
equipment may be impaired if 
accessories used are no provided 
or recommended by
the manufacturer, or are used in a 
manner not specified by the 
manufacturer.

CAUTION !

 To avoid electrical 

shock, completely cut off power to 
the unit by disconnecting the 
power cord from the unit
or unplug from the wall outlet. 
Disconnect unit from the power 
supply prior to maintenance and 
service. Any spills should
be removed promptly. Bio hazard 
spills should be cleaned using 
approved liquid promptly. Solvent 
spills are a fire hazard.

Storage Environmental Conditions
Temperature..................................0 to 60

Humidity.....20% to 90%, non-condensing

Stop the unit immediately, and DO 
NOT operate until clean up is 
complete and vapors have 
dissipated.

DO NOT 

immerse the unit for 

cleaning.

DO NOT 

operate the unit if it shows 

signs of electrical or mechanical 
damage.

Note: 

The rotary plate may have a

little vibration below 11 rpm. The
vibration will relieve or disappear when
more load is added.

Various independent clamps are 
available with this Digital Cel-Gro Tissue 
Culture Rotator  for convenient 
combination use. It is applicable for 
1.5ml to 50ml  microtubes to mix liquid 
efficiently and gently. It has an angle 
range of 95 to 180 degrees and can 
maintain suspension state of biological 
samples such as blood mixing. 
Applications include blood coagulation 
prevention, emulsion diagnosis, 
immunoprecipitation, and other related 
areas.

7      Section 4  |  Overview

Digital Cel-Gro Tissue Culture Rotator      8

Run

Run

Stop

Speed

Time

rpm

+

-

+

-

Section 5  Operation

This chapter covers the control panel and its operation.

5.1 Control Panel

.   Run/Stop button: Start or stop the 

      instrument.

.  Run indicator: The light is on when 

      the instrument is running and off 
      when the instrument is in standby.

.  Time display window: The window 

      displays cumulative time (in 
      continuous mode) or remaining time 
      (in timer mode). 

.  Speed display window: The window 

      displays set speed (when the 
      instrument is in standby) or current 
      speed (when the instrument is 
      running).


Summary of Contents for 88882015

Page 1: ...e thermofisher com Find out more at thermofisher com In Canada For customer service call 1 800 234 7437 To fax an order use 1 800 463 2996 To order online thermofisher ca Operating Manual Revision A 04 01 2021 2021 Thermo Fisher Scientific Inc All rightsreserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified ...

Page 2: ...ction 4 Overview Specifications Environmental Conditions Safety Instructions Section 5 Operation Control Panel Installation Accessory Installation Settings Section 6 Safety Tips and Maintenance Section 7 Troubleshooting Section 8 Optional Accessories Section 9 Warranty Information Section 10 Compliance Contents 1 2 3 4 4 5 5 6 6 6 7 8 8 9 9 13 15 16 17 19 20 ...

Page 3: ...uation if not avoided may result in minor or moderate injury Indicates a hazardous situation which if not avoided may result in minor or moderate injury Do not put heavy things on the power cord Do not put the machine on the cord It may take off the wire coating and cause electric shock or fire Do not touch it with wet hands and place the main plug correctly It could cause the electric shock or in...

Page 4: ...various volume tissue culture Rotator is designed for the different application such as schools laboratories hospitals Rotator is used for routine blood test and other mixing applications This product is intended to be used in a laboratory setting and is not to be used in a clinical setting Section 3 Inspection and Installation Table 1 Packing List General Power Adaptor US Plug CN Plug EU Plug UK ...

Page 5: ...Range 95 180 Angle Accuracy 2 Max Load Contain rotator drum weight 5kg Timing Range 0 9999min Overall Dimensions 383 260 412mm Packaging Dimensions 486 381 470mm Net Weight 8 2Kg 18 1lb Gross Weight 10 4Kg 22 9lb Input Requirement 100 240VAC 50 60Hz 8W 0 2A Output Requirement 24V 2 5A Certification RoHS WEEE cCSAus CE Mark Noise Level 55dB with no load Application Environmental Conditions indoor u...

Page 6: ...erature 0 to 60 Humidity 20 to 90 non condensing Stop the unit immediately and DO NOT operate until clean up is complete and vapors have dissipated DO NOT immerse the unit for cleaning DO NOT operate the unit if it shows signs of electrical or mechanical damage Note The rotary plate may have a little vibration below 11 rpm The vibration will relieve or disappear when more load is added Various ind...

Page 7: ...s 1 Turn the motor housing back and forth gently by hand and pull the bolt up at the same time Digital Cel Gro Tissue Culture Rotator 10 2 If the bolt still cannot be pulled out please use vise grip plier to pull the bolt up and turn the motor housing at the same time 3 Please contact us immediately if the problem still exists 2 Rotate the motor housing gently by hand to adjust the angle 3 Insert ...

Page 8: ... is possible for the tray to exhibit uneven or erratic rotation This does not necessarily indicate equipment malfunction and a cause for returning the unit to the manufacturer Loading and Unloading the Tray 1 Insert or remove culture tubes starting from the center to the outside edge of the tray 2 Make sure the weight is distributed evenly on the tray 3 Maintain the overall balance of the tray esp...

Page 9: ...hown on the Time display window starts flashing turn the knob to increase or decrease the time value Press the knob when the time shown on the Time display window reaches the set value within 5s Speed Settings Press the Speed setting knob When the Speed display window starts flashing turn the knob to increase or decrease the speed value Press the knob when the speed shown on the Speed display wind...

Page 10: ...ment please shut down the instrument and clean up the liquid immediately If the liquid has already spilled into the unit cut off the power supply first and immediately clean up the liquid at the surface of the instrument Place the instrument in a ventilated and dry environment for 24 hours before reuse If the instrument is not functioning after drying for 24 hours please contact the manufacturer W...

Page 11: ...Drum 88882155 1 Ø380 78mm 142xØ17mm Rotator Drum 88882154 1 Ø310 115mm 64x18 5mm Rotator Drum Digital Cel Gro Tissue Culture Rotator 18 Description Cat No Max Qty Figure Dimensions General Power Adaptor w US plug 88870127 88870128 88870129 88870126 1 1 1 1 General Power Adaptor w AUS CN plug General Power Adaptor w EU plug General Power Adaptor w UK plug 125VAC 10A 1 8m 250VAC 10A 1 8m 250VAC 16A ...

Page 12: ...e the USA please contact local Thermo Technical Services Department or local distributor for warranty information Digital Cel Gro Tissue Culture Rotator 20 Section 10 Compliance 1 European Union The European voltage models of this product meet all the applicable requirements of the European Directives and therefore display the CE Marking These Directives are captured in the EU Declaration of Confo...

Page 13: ...th the requirements of the legislative act Administration on the Control of Pollution Caused by Electronic Information Products ACPEIP A label of conformance such as one of the following may be found on the product 5 End of Life Care Some considerations and suggestions are listed below for proper disposal of this product While addressing these actions for safe recycling and disposal please follow ...

Reviews: