17      Section 8  |  Optional Accessories

Section 8 Optional Accessories

Ø

290×24mm

50x1.5/2.0ml  
Rotator Drum

88882149

88882150

88882151

88882152

88882153

88882157

Ø

290×31mm

1

1

1

1

1

1

Ø

290×48mm

Ø

310×75mm

Ø

290×31mm

Ø

380x78mm

10x10/15ml + 
20x5/7ml Drum 

30x15ml 
Rotator Drum

15x50ml
 Rotator Drum

64x14mm 
Rotator Drum

60x

Ø

30mm 

Rotator Drum

88882156

1

Ø

380×73mm

76x

Ø

26mm 

Rotator Drum

88882155

1

Ø

380×78mm

142x

Ø

17mm 

Rotator Drum

88882154

1

Ø

310×115mm

64x18.5mm 
Rotator Drum

Digital Cel-Gro Tissue Culture Rotator      18

Description

Cat. No.

Max. Qty.

Figure

Dimensions

General Power Adaptor
w/US plug

88870127

88870128

88870129

88870126

1

1

1

1

General Power Adaptor
w/AUS, CN plug

General Power Adaptor
w/EU plug

General Power Adaptor
w/UK plug

125VAC 10A 1.8m

250VAC 10A 1.8m

250VAC 16A 1.8m

250VAC13A 1.8m

Description

Cat. No.

Max. Qty.

Figure

Dimensions

Note:

Minimum angle adjustment for Double Tray Drum ( 88882153 / 88882154 / 
88882155 /88882156 / 88882157 ) is 112

°

Summary of Contents for 88882015

Page 1: ...e thermofisher com Find out more at thermofisher com In Canada For customer service call 1 800 234 7437 To fax an order use 1 800 463 2996 To order online thermofisher ca Operating Manual Revision A 04 01 2021 2021 Thermo Fisher Scientific Inc All rightsreserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified ...

Page 2: ...ction 4 Overview Specifications Environmental Conditions Safety Instructions Section 5 Operation Control Panel Installation Accessory Installation Settings Section 6 Safety Tips and Maintenance Section 7 Troubleshooting Section 8 Optional Accessories Section 9 Warranty Information Section 10 Compliance Contents 1 2 3 4 4 5 5 6 6 6 7 8 8 9 9 13 15 16 17 19 20 ...

Page 3: ...uation if not avoided may result in minor or moderate injury Indicates a hazardous situation which if not avoided may result in minor or moderate injury Do not put heavy things on the power cord Do not put the machine on the cord It may take off the wire coating and cause electric shock or fire Do not touch it with wet hands and place the main plug correctly It could cause the electric shock or in...

Page 4: ...various volume tissue culture Rotator is designed for the different application such as schools laboratories hospitals Rotator is used for routine blood test and other mixing applications This product is intended to be used in a laboratory setting and is not to be used in a clinical setting Section 3 Inspection and Installation Table 1 Packing List General Power Adaptor US Plug CN Plug EU Plug UK ...

Page 5: ...Range 95 180 Angle Accuracy 2 Max Load Contain rotator drum weight 5kg Timing Range 0 9999min Overall Dimensions 383 260 412mm Packaging Dimensions 486 381 470mm Net Weight 8 2Kg 18 1lb Gross Weight 10 4Kg 22 9lb Input Requirement 100 240VAC 50 60Hz 8W 0 2A Output Requirement 24V 2 5A Certification RoHS WEEE cCSAus CE Mark Noise Level 55dB with no load Application Environmental Conditions indoor u...

Page 6: ...erature 0 to 60 Humidity 20 to 90 non condensing Stop the unit immediately and DO NOT operate until clean up is complete and vapors have dissipated DO NOT immerse the unit for cleaning DO NOT operate the unit if it shows signs of electrical or mechanical damage Note The rotary plate may have a little vibration below 11 rpm The vibration will relieve or disappear when more load is added Various ind...

Page 7: ...s 1 Turn the motor housing back and forth gently by hand and pull the bolt up at the same time Digital Cel Gro Tissue Culture Rotator 10 2 If the bolt still cannot be pulled out please use vise grip plier to pull the bolt up and turn the motor housing at the same time 3 Please contact us immediately if the problem still exists 2 Rotate the motor housing gently by hand to adjust the angle 3 Insert ...

Page 8: ... is possible for the tray to exhibit uneven or erratic rotation This does not necessarily indicate equipment malfunction and a cause for returning the unit to the manufacturer Loading and Unloading the Tray 1 Insert or remove culture tubes starting from the center to the outside edge of the tray 2 Make sure the weight is distributed evenly on the tray 3 Maintain the overall balance of the tray esp...

Page 9: ...hown on the Time display window starts flashing turn the knob to increase or decrease the time value Press the knob when the time shown on the Time display window reaches the set value within 5s Speed Settings Press the Speed setting knob When the Speed display window starts flashing turn the knob to increase or decrease the speed value Press the knob when the speed shown on the Speed display wind...

Page 10: ...ment please shut down the instrument and clean up the liquid immediately If the liquid has already spilled into the unit cut off the power supply first and immediately clean up the liquid at the surface of the instrument Place the instrument in a ventilated and dry environment for 24 hours before reuse If the instrument is not functioning after drying for 24 hours please contact the manufacturer W...

Page 11: ...Drum 88882155 1 Ø380 78mm 142xØ17mm Rotator Drum 88882154 1 Ø310 115mm 64x18 5mm Rotator Drum Digital Cel Gro Tissue Culture Rotator 18 Description Cat No Max Qty Figure Dimensions General Power Adaptor w US plug 88870127 88870128 88870129 88870126 1 1 1 1 General Power Adaptor w AUS CN plug General Power Adaptor w EU plug General Power Adaptor w UK plug 125VAC 10A 1 8m 250VAC 10A 1 8m 250VAC 16A ...

Page 12: ...e the USA please contact local Thermo Technical Services Department or local distributor for warranty information Digital Cel Gro Tissue Culture Rotator 20 Section 10 Compliance 1 European Union The European voltage models of this product meet all the applicable requirements of the European Directives and therefore display the CE Marking These Directives are captured in the EU Declaration of Confo...

Page 13: ...th the requirements of the legislative act Administration on the Control of Pollution Caused by Electronic Information Products ACPEIP A label of conformance such as one of the following may be found on the product 5 End of Life Care Some considerations and suggestions are listed below for proper disposal of this product While addressing these actions for safe recycling and disposal please follow ...

Reviews: