background image

19      Section 9  |  Warranty

Section 9 Warranty

THERMO FISHER SCIENTIFIC 
STANDARD PRODUCT WARRANTY

The Warranty Period starts two weeks 
from the date your equipment is shipped 
from our facility. This allows for shipping 
time so the warranty will go into effect at 
approximately the same time your 
equipment is delivered. The warranty 
protection extends to any subsequent 
owner during the first year warranty 
period.

During the first two (2) years, component 
parts proven to be non-conforming in 
materials or workmanship will be 
repaired or replaced at Thermo's 
expense, labor included. Installation and 
calibration are not covered by this 
warranty agreement. The Technical 
Services Department must be contacted 
for warranty determination and direction 
prior to performance of any repairs. 
Expendable items, glass, filters and 
gaskets are excluded from this warranty.

Replacement or repair of components 
parts or equipment under this warranty 
shall not extend the warranty to either 
the equipment or to the component part 
beyond the original warranty period. The 
Technical Services Department must 
give prior approval for return of any 
components or equipment. At Thermo's 
option, all non-conforming parts must 
be returned to Thermo Fisher Scientific 
postage paid and replacement parts are 
shipped FOB destination.

THIS WARRANTY IS EXCLUSIVE AND IN 
LIEU OF ALL OTHER WARRANTIES, 
WHETHER WRITTEN, ORAL OR IMPLIED. 
NO WARRANTIES OF 
MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE SHALL APPLY. 
Thermo shall not be liable for any 
indirect or consequential damages 
including, without limitation, damages 
relating to lost profits or loss of 
products.

Your local Thermo Sales Office is ready 
to help with comprehensive site 
preparation information before your 
equipment arrives. Printed instruction 
manuals carefully detail equipment 
installation, operation and preventive 
maintenance.

If equipment service is required, please 
call your Technical Services Department 
at 1-866-984-3766, option number 2. 
We're ready to answer your questions on 
equipment warranty, operation, 
maintenance, service and special 
application. Outside the USA, please 
contact local Thermo Technical Services 
Department or local distributor for 
warranty information.

Digital Cel-Gro Tissue Culture Rotator      20

Section 10 Compliance

1. European Union

                   The European voltage models                                         
                   of this product meet all the 
applicable requirements of the European 
Directives and therefore display the CE 
Marking. These Directives are captured 
in the EU Declaration of Conformity 
which may be obtained from the 
manufacturer. 

2.  Product Safety

This product family has been tested to 
applicable productsafety standards by a 
Nationally Recognized Test Laboratory 
(NRTL) and may bear the NRTL's mark of 
safety compliance to those applicable 
standards.

3.

 Electromagnetic Compatibility

3.1 FCC Statement (USA)

                   Any changes or modifications 
                   not expressly approved by the 
party responsible for compliance could 
void the user's authority to operate the 
equipment.

Note: 

This equipment has been tested 

and found to comply with the limits for a 
Class B digital device, pursuant to part 
15 of the FCC Rules. These limits are 
designed to provide reasonable 
protection against harmful interference 
when the equipment is operated in a 
commercial environment. This 
equipment generates, uses, and can 
radiate radio frequency energy and, if not 
installed and used in accordance with

 the instruction manual, may cause 
harmful interference to radio 
communications. Operation of this 
equipment in a residential area is likely to 
cause harmful interference in which 
case the user will be required to correct 
the interference at his own expense.

3.2 Canadian ISED IC Notice
This ISM digital apparatus complies with 
Canadian ICES-001.
Cetappareil ISM estconformeá la norme 
NMB-001 du Canada.owing optimum 
tray rotation.

3.3 Korean KC Registration
              

사용자안내문

              

이기기는엄무용환경에서사용할

              

목적으로적함성평가를받은기기

로서가정용환경에서사용하는경우전파
간섬의우려가있습니다

WARNING Statement: EMC Registration 
is done on this equipment for business 
use only. It may cause interference when 
the product would be used in home. This 
warning statement applies a product for 
business use.

4. Environmental Compliance

4.1 Evaluation of Chemicals -
Regulations and Directives
4.1.1 REACH - Europe
                 Thermo Fisher Scientific is   
                 committed to meeting all 
compliance obligations to evaluate, 
communicate, and register any 
Substances of Very High Concern 
(SVHC), and finding alternates where 

Summary of Contents for 88882015

Page 1: ...e thermofisher com Find out more at thermofisher com In Canada For customer service call 1 800 234 7437 To fax an order use 1 800 463 2996 To order online thermofisher ca Operating Manual Revision A 04 01 2021 2021 Thermo Fisher Scientific Inc All rightsreserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified ...

Page 2: ...ction 4 Overview Specifications Environmental Conditions Safety Instructions Section 5 Operation Control Panel Installation Accessory Installation Settings Section 6 Safety Tips and Maintenance Section 7 Troubleshooting Section 8 Optional Accessories Section 9 Warranty Information Section 10 Compliance Contents 1 2 3 4 4 5 5 6 6 6 7 8 8 9 9 13 15 16 17 19 20 ...

Page 3: ...uation if not avoided may result in minor or moderate injury Indicates a hazardous situation which if not avoided may result in minor or moderate injury Do not put heavy things on the power cord Do not put the machine on the cord It may take off the wire coating and cause electric shock or fire Do not touch it with wet hands and place the main plug correctly It could cause the electric shock or in...

Page 4: ...various volume tissue culture Rotator is designed for the different application such as schools laboratories hospitals Rotator is used for routine blood test and other mixing applications This product is intended to be used in a laboratory setting and is not to be used in a clinical setting Section 3 Inspection and Installation Table 1 Packing List General Power Adaptor US Plug CN Plug EU Plug UK ...

Page 5: ...Range 95 180 Angle Accuracy 2 Max Load Contain rotator drum weight 5kg Timing Range 0 9999min Overall Dimensions 383 260 412mm Packaging Dimensions 486 381 470mm Net Weight 8 2Kg 18 1lb Gross Weight 10 4Kg 22 9lb Input Requirement 100 240VAC 50 60Hz 8W 0 2A Output Requirement 24V 2 5A Certification RoHS WEEE cCSAus CE Mark Noise Level 55dB with no load Application Environmental Conditions indoor u...

Page 6: ...erature 0 to 60 Humidity 20 to 90 non condensing Stop the unit immediately and DO NOT operate until clean up is complete and vapors have dissipated DO NOT immerse the unit for cleaning DO NOT operate the unit if it shows signs of electrical or mechanical damage Note The rotary plate may have a little vibration below 11 rpm The vibration will relieve or disappear when more load is added Various ind...

Page 7: ...s 1 Turn the motor housing back and forth gently by hand and pull the bolt up at the same time Digital Cel Gro Tissue Culture Rotator 10 2 If the bolt still cannot be pulled out please use vise grip plier to pull the bolt up and turn the motor housing at the same time 3 Please contact us immediately if the problem still exists 2 Rotate the motor housing gently by hand to adjust the angle 3 Insert ...

Page 8: ... is possible for the tray to exhibit uneven or erratic rotation This does not necessarily indicate equipment malfunction and a cause for returning the unit to the manufacturer Loading and Unloading the Tray 1 Insert or remove culture tubes starting from the center to the outside edge of the tray 2 Make sure the weight is distributed evenly on the tray 3 Maintain the overall balance of the tray esp...

Page 9: ...hown on the Time display window starts flashing turn the knob to increase or decrease the time value Press the knob when the time shown on the Time display window reaches the set value within 5s Speed Settings Press the Speed setting knob When the Speed display window starts flashing turn the knob to increase or decrease the speed value Press the knob when the speed shown on the Speed display wind...

Page 10: ...ment please shut down the instrument and clean up the liquid immediately If the liquid has already spilled into the unit cut off the power supply first and immediately clean up the liquid at the surface of the instrument Place the instrument in a ventilated and dry environment for 24 hours before reuse If the instrument is not functioning after drying for 24 hours please contact the manufacturer W...

Page 11: ...Drum 88882155 1 Ø380 78mm 142xØ17mm Rotator Drum 88882154 1 Ø310 115mm 64x18 5mm Rotator Drum Digital Cel Gro Tissue Culture Rotator 18 Description Cat No Max Qty Figure Dimensions General Power Adaptor w US plug 88870127 88870128 88870129 88870126 1 1 1 1 General Power Adaptor w AUS CN plug General Power Adaptor w EU plug General Power Adaptor w UK plug 125VAC 10A 1 8m 250VAC 10A 1 8m 250VAC 16A ...

Page 12: ...e the USA please contact local Thermo Technical Services Department or local distributor for warranty information Digital Cel Gro Tissue Culture Rotator 20 Section 10 Compliance 1 European Union The European voltage models of this product meet all the applicable requirements of the European Directives and therefore display the CE Marking These Directives are captured in the EU Declaration of Confo...

Page 13: ...th the requirements of the legislative act Administration on the Control of Pollution Caused by Electronic Information Products ACPEIP A label of conformance such as one of the following may be found on the product 5 End of Life Care Some considerations and suggestions are listed below for proper disposal of this product While addressing these actions for safe recycling and disposal please follow ...

Reviews: