CSR-20 & CSR-40, September 1999
Introduction
CSR Features
vii
CSR Model Features (Continued)
X
X
X
X
X
X
X
X
X
460-380V/3Ph/60-50 Hz, 18.3 m (60 ft) Power Cable and Plug
–
–
–
–
–
–
–
–
–
Dual Voltage Feature: 15 kVA Autotransformer with 460-380V Power Receptacle and 230-
190V/3Ph/60-50 Hz, 18.3 m (60 ft) Power Cable and Plug
X
X
X
X
X
X
X
X
X
Automatic Phase Selection Control
X
X
X
X
X
X
X
X
X
25 Amp Main Power Circuit Breaker
–
–
X
X
–
–
–
–
X
Slimline Frame
X
X
X
X
X
X
X
X
X
Hermetic Scroll Compressor w/4.48 kW (6.0 Hp) Motor
X
X
X
X
X
X
X
X
X
Hermetic Refrigeration System
X
X
X
X
X
X
X
X
X
Compressor Liquid Injection System
X
X
X
X
X
X
X
X
X
Warm Gas Bypass Valve System
X
X
X
X
X
X
X
X
X
Modulation Valve
X
X
X
X
X
X
X
X
X
Refrigerant R-404A w/Polyol Ester Compressor Oil (TK P/N 203-433)
X
X
X
X
X
X
X
X
X
Receiver Tank
X
X
X
X
X
X
X
X
X
µ
P-D Controller with Proportional-integral Differential (PID) Capacity Control
X
X
X
X
X
X
X
X
X
Controller Emergency Bypass Module
X
X
X
X
X
X
X
X
X
USDA Cold Treatment Temperature Recording
–
–
X
X
–
–
–
–
X
Three Evaporator Fans with 2-Speed Motors
X
X
–
–
X
X
X
X
–
Two Evaporator Fans with 2-Speed Motors
X
X
X
X
X
X
X
X
X
Fresh Air Exchange System
X
X
X
X
X
X
X
X
X
CO2 Sampling Port
X
X
X
X
X
X
X
X
X
One 1-Speed Condenser Fan Motor
–
–
X
X
X
X
–
–
–
Auxiliary Battery and Battery Charger
–
–
–
–
–
–
–
–
–
Bulb Mode Operation
–
–
–
–
–
–
–
–
–
Controlled Atmosphere System
X
X
X
X
X
X
X
X
X
Data Retrieval Receptacle, Standard (5-Pin Duetsch)
–
–
–
–
–
–
–
–
–
Data Retrieval Receptacle, 5-Pin Threaded Cannon
–
–
–
–
–
–
–
–
–
Data Retrieval Receptacle, 15-Pin RS232
X
–
X
–
X
–
–
–
–
Dehumidify Control
–
–
X
X
–
–
–
–
–
Humidity System
–
–
–
–
–
–
–
–
–
Power Line Communications, Standard (Thermo King Modem)
–
–
–
–
–
–
–
–
–
Power Line Communications, Thermo King Integrated Remote Monitor Unit (IRMU)
–
–
–
–
–
–
–
–
–
Power Line Communications, RTE Modem
–
–
X
X
–
–
–
–
–
Power Line Communications, Sabroe Control Modem
–
–
–
–
–
X
–
–
–
Recorder, Partlow
–
X
–
–
–
–
–
X
X
Recorder, Saginomiya
–
–
–
–
–
–
–
–
–
Redundant Supply and Return Sensors
–
–
–
–
X
X
–
–
–
Remote Monitoring Plug (4-Pin)
–
–
–
–
X
–
–
–
–
TRANSFRESH
®
Provision
–
–
–
–
–
–
–
–
–
TRANSFRESH
®
Purge Port
–
–
X
X
–
–
–
–
–
TRANSFRESH
®
System, Complete
–
–
–
–
X
X
–
–
–
Thermistor Lead
–
–
–
–
–
–
X
–
–
Water-Cooled Condenser-Receiver Tank
CSR-40-128
CSR-40-129
CSR-40SL-130
CSR-20SL-131
CSR-40-134
CSR-40-136
CSR-40-139
CSR-40-140
CSR-40SL-142
FEATURES
X = Included
MODEL