4-24
Menu View Functions
µ
P-D Controller
CSR-20 & CSR-40, September 1999
To enter the TEMP scrollback submenu:
1.
Press the SELECT key with “LOG TEMP” in the display.
Display will briefly show “SEARC HINGX”. The display
then shows the last (most recent) data log entry (e.g.
“001RT 43.8F”).
2.
Press Up or DOWN key to scroll (up or down) through
the last 100 data log entries of the return air temperature.
3.
Press the SELECT key to scroll (to the right) to the next
column of data. The display wraps around from T1 (Time)
screen to RT (Return Temperature) screen. Press the
RET/SUP key to quickly return to the RT (return tempera-
ture) display.
NOTE: If a log entry for a sensor was not recorded,
the right display will show “NOLOG”.
NOTE: The controller returns to the “LOG TEMP”
screen from a data log screen after 10 seconds if no
controller key is pressed. The controller returns to
the Standard Display after another 10 seconds, or
when the SELECT key is pressed and held for 3 sec-
onds.
PTI Scrollback Display Items
The PTI scrollback display also contains a lot of informa-
tion. After entering the PTI display (“PT1 PASS” or “PT1
FAIL” appears), imagine that the data is stored in a table. The
first column identifies the number of the Full Pretrip test (PT1,
PT2, etc.) and the test result (PASS or FAIL). Each additional
column identifies information about an individual test result or
the time of the test.
The PTI scrollback display shows the following acronyms
and information:
DS Display Test Result
AM Amps Test Result
SN Sensors Test Result
HT Heat Test Result
DF Defrost Test Result
CL Cool Test Result
EX Extended Cool Test Result
YR Year
MO Month
DY Day
TI Time
To enter the PTI scrollback submenu:
1.
Press the SELECT key with “LOG PTI” in the display.
Display will show the result of the last (most recent) Full
Pretrip test (e.g. “PT1 FAIL” or “PT1 PASS”).
2.
Press UP key to scroll back through the last 4 Full Pretrip
test entries.
3.
Press the SELECT key to scroll (to the right) to the next
individual test result stored with each Full Pretrip test (e.g.
“PT1DS PASS”). Display wraps around the TI (Time)
screen to DS (Display Test) screen. Press the RET/SUP
key to quickly return to the DS (Display Test) screen.
NOTE: If a log entry for a sensor was not record-
ed, the right display will show “NOLOG”.
NOTE: The controller returns to the “LOG PTI”
screen from a pretrip log screen after 30 sec-
onds. To return to the Standard Display, press
and hold the SELECT key for 3 seconds.