![Thermo King 914970 Manual Download Page 18](http://html1.mh-extra.com/html/thermo-king/914970/914970_manual_1104406018.webp)
Specifications
16
R-134a Refrigeration System
Compressor Model
Thermo King X426
Refrigerant Charge
9 lb. (4.1 kg) R-134a
Compressor Oil Charge
4 qt 6 oz. (3.9 liters)*
Compressor Oil Type
TK No. 203-413 (Ester base) required
Throttle Valve Setting
18 to 20 psig (124 to 138 kPa)
Heat/Defrost Method:
Engine Operation
Electric Operation
Hot gas
Hot gas and electric heater strips (Model 50)
High Pressure Cutout
470 ± 7 psig (3241 ± 48 kPa)
Automatically reset @ 375 ± 38 psig (2586 ± 262 kPa)
Electronic Defrost Termination Timer:
Opens
Closes
52 F (11.1 C)
42 F (5.6 C)
Timer—Part of TG-V Microprocessor
Programmable 2 to 16 hours in 2 hour increments
through TGV controller
* When the compressor is removed from the unit, oil level should be noted or the oil removed from the compressor should be
measured so that the same amount of oil can be added before placing the replacement compressor in the unit.
R-404A Refrigeration System
Compressor Model
Thermo King X426
Refrigerant Charge
8 lb. (3.63 kg) R-404A
Compressor Oil Charge
4 qt 6 oz. (3.9 liters)*
Compressor Oil Type
Solest 35 TK No. 203-413 (Ester base) required
Throttle Valve Setting
18 to 20 psig (124 to 138 kPa)
Heat/Defrost Method:
Engine Operation
Electric Operation
Hot gas
Hot gas and electric heater strips (Model 50)
High Pressure Cutout
450 ± 10 psig (3103 ± 69 kPa)
Automatically reset @ 375 ± 38 psig (2585 ± 262 kPa)
Electronic Defrost Termination Timer:
Opens
Closes
52 F (11 C)
42 F (6 C)
Timer—Part of TG-V Microprocessor
Programmable 2 to 16 hours in 2 hour increments
through TGV controller
* When the compressor is removed from the unit, oil level should be noted or the oil removed from the compressor should be
measured so that the same amount of oil can be added before placing the replacement compressor in the unit.
Engine Clutch
Model
TK No. 107-257
Engagement
900 ± 100 RPM
Dynamic Torque
66 ft-lb (89.5 N•m) minimum @ 1600 RPM
Summary of Contents for 914970
Page 3: ...3...
Page 10: ...Table of Contents 10...
Page 40: ...Operating Instructions 40...
Page 82: ...Electronic Controls 82...
Page 92: ...Electrical Maintenance 92...
Page 124: ...Refrigeration Maintenance 124...
Page 140: ...Hilliard Clutch Maintenance 140...
Page 160: ...Refrigeration Diagrams 160...
Page 163: ...Index 163 W wiring 85 wiring diagrams 165...
Page 164: ...Index 164...
Page 166: ...Wiring and Schematic Diagrams Index 166...
Page 167: ...167 Cab Control RD Wiring Diagram...
Page 168: ...168 RD w o Thermostat Cab Control Schematic...
Page 169: ...169 RD Cab Box Wiring Diagram...
Page 170: ...170 RD Cab Control w Thermostat Schematic Diagram...
Page 171: ...171 RD 50 STD 3 Phase Wiring Diagram Page 1 of 2...
Page 172: ...172 RD 50 STD 3 Phase Wiring Diagram Page 2 of 2...
Page 173: ...173 RD 50 STD 3 Phase Schematic Diagram Page 1 of 2...
Page 174: ...174 RD 50 STD 3 Phase Schematic Diagram Page 2 of 2...
Page 175: ...175 RD 30 STD Wiring Diagram Page 1 of 2...
Page 176: ...176 RD 30 STD Wiring Diagram Page 2 of 2...
Page 177: ...177 RD 30 STD Schematic Diagram Page 1 of 2...
Page 178: ...178 RD 30 STD Schematic Diagram Page 2 of 2...
Page 179: ...179 RD 30 C S Wiring Diagram Page 1 of 2...
Page 180: ...180 RD 30 C S Wiring Diagram Page 2 of 2...
Page 181: ...181 RD w CYCLE SENTRY Schematic Diagram Page 1 of 2...
Page 182: ...182 RD w CYCLE SENTRY Schematic Diagram Page 2 of 2...
Page 183: ...183 RD 50 C S 3 Phase Wiring Diagram Page 1 of 2...
Page 184: ...184 RD 50 C S 3 Phase Wiring Diagram Page 2 of 2...
Page 185: ...185 RD w CYCLE SENTRY Schematic Diagram Page 1 of 2...
Page 186: ...186 RD w CYCLE SENTRY Schematic Diagram Page 2 of 2...