AUTO-CUT 300 XT
Manual 0-5300
APPENDIX
A-63
303
Gas Pressure fault
Gas pressure faults only show up when you try to start the torch, not during purging or setting flows .
With the Auto-Cut 200 XT and the Auto-Cut 300 XT (GCM 1000 XT), the gas pressure sensor is only on the
plasma gas and is in series with Run/Set switch. A 303 code here indicates either plasma gas missing or very
low pressure, less than 50 PSI, or RUN/SET switch is in SET position.
Starting with GCM2010 revision AG we measure inlet pressure of both plasma and shield gas at the inlet of
the gas selection manifold. If pressure is either too low or too high it sets 303 code. Earlier revision should not
display 303 code. GCM2010 will display which gas is the problem and its actual pressure. The pressure at the
point where it is measured should be in the range of 100-135 PSI. Exception is for shield gas if the Gas switch
is set to Pressure then the min pressure can be 85 PSI.
In the GCM 2010 Gas Control, on the main PCB, measure between test points TP1 (ground) and TP18 (shield)
and TP19 (plasma) to measure the output of the pressure sensors. Voltage should be between 2.6V to 3.5V for
100-135 PSI. With shield switch set to pressure low limit is 2.1V. Whichever gas is outside those limits will
be the one causing the fault. Remember the pressure may drop during operation, set the code, then recover
displaying L303 when you are measuring it.
• To test for faulty pressure sensor or inadequate gas supply with too much restriction. On the GCM 2010
place the Mode switch to SET Plasma & Shield, turn the mechanical pressure regulators to max pressure
and compare mechanical gauges with the pressure display. If the pressure display doesn’t approximately
match the gauge the sensor is likely defective. If the gauge and the pressure display both show low pres
-
sure the supply to the gas control has too much restriction. Perhaps the hose is too long or too small.
304
Gas Control not ready
This is the normal code when the gas control is conducting a purge at start up or when the process is loaded
or changed or when the plasma system has been disabled and is returned to “Enable”. If it is a GCM 2010 the
Mode switch may not be set to the RUN mode.
Code 304 combined with 204 & 402 when the Plasma Enable on the GCM 2010 gas control is set to disable can
indicate a fault in the CCM I/O PCB. When switching back to Enabled the pump will not restart so continues
to display 4-2 indicating no coolant flowing.
Normally the code during a disable should be 101. Circuits on the I/O PCB detect the Plasma Enable is disabled
and send signal to the microcontroller in the CCM. If a fault in the CCM prevents that signal from getting sent
to the microcontroller it doesn’t know the system is disabled so it sets these other 3 codes.
305
Gas Control Protocol Error
Application error or firmware incompatibility fault. Consult factory for latest firmware update. Possible elec
-
tromagnetic interference from the Arc Starter; inspect grounding, bonding, and isolation.
306
Not Used. This is one of the reserved codes from the earlier product.
307
Gas Control returns wrong command sequence.
Firmware incompatibility. Consult factory for latest firmware update. Possible electromagnetic interference
from the Arc Starter; inspect grounding; bonding; and isolation.
308
Mismatch between the CCM and gas control type.
The Auto-Cut XT CCM is designed to work with the GCM 1000 (AC 300 XT) or the built in gas control of the AC
200 XT. Attempting to use a GCM 2010 or DFC 3000 Auto Gas Control on an Auto-Cut will result in a 308 code.
Similarly attempting to use a CCM from an Auto-Cut XT in an Ultra-Cut XT supply will also result in a 308 code.
309
Gas Control Communication reply fault.
Relay doesn’t match what was requested. Possible firmware incompatibility. Consult factory for latest firm
-
ware update.
Possible electromagnetic interference from the Arc Starter; inspect grounding; bonding; and isolation.
Summary of Contents for AUTO-CUT 300 XT
Page 6: ...This Page Intentionally Blank...
Page 13: ...AUTO CUT 300 XT Manual 0 5300 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 52: ...This Page Intentionally Blank...
Page 105: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 19 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Page 114: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 11 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 115: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 29 APPENDIX 12 Cap Bias Top PCB Layout Art A 11686_AB...
Page 116: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 13 Suppressor PCB Layout Art A 11684_AB...
Page 161: ......