AUTO-CUT 300 XT
Manual 0-5300
APPENDIX
A-55
Possible causes:
• Wrong voltage inverter (very unlikely but easy to check).
• System Bias board wrong J61 jumper (unlikely but easy to check)
• Defective inverter.
• Ribbon Cable
• CCM
• System Bias board defective.
Troubleshooting:
1. If System Bias board has either the wrong jumper or is defective it will call out the first inverter section, code
231, because all the inverters won’t match the incorrect signal and 1A is checked first.
a. For the jumper Wire #48 should be connected from J61-1 to:
i. J61-2 for 208-230 VAC
ii. J61-3 for 400 VAC
iii. J61-4 for 480 VAC
Check for proper connection and continuity.
b. System Bias may be defective reporting the wrong voltage ID. On the output of the System Bias board
at J62 measure relative to TP1 or ( J62-8, 24VDC_RET) to J62-12 for signal /VAC_IDAb and J62-14 for
signal /VAC_IDBb. The 2 signals should read according to this table. “0” = 10-12V; “1” = 24V.
signal
230V �00V ��0V
ERR
/VAC_IDAb
0
1
0
1
/VAC_IDBb
0
0
1
1
2. Defective inverter, ribbon cable or CCM.
a. On the inverter section swap the ribbon cable of the inverter section whose fault was indicated with that
of a different inverter section. If fault remains unchanged, still calls out the original inverter section, the
problem is with either ribbon cable or CCM. If fault changes to the different section, the one the ribbon
cable was swapped with, then it’s the inverter that’s defective.
b. If the fault remained unchanged in Step A, on the inverter end, put the ribbon cables back in their original
positions. Now swap suspect ribbon cable with another one on the CCM. If the fault now moves to a
different section it’s the ribbon cable. If it remains with the original section the problem is the CCM.
237
Too Few Inverters Found
There must be a minimum of 2 inverter sections present to operate. We know the ribbon cable for inverter sec
-
tion 1A is connected or else we would have code 224. During the power up sequence, before power is connected
to the inverters, the CCM does a continuity test through the ribbon cable to see if an inverter is connected. If it
doesn’t see continuity with at least one other inverter it assumes none are connected.
Possible causes:
• Ribbon cable disconnected or defective.
• Inverter defective
• CCM defective.
Summary of Contents for AUTO-CUT 300 XT
Page 6: ...This Page Intentionally Blank...
Page 13: ...AUTO CUT 300 XT Manual 0 5300 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 52: ...This Page Intentionally Blank...
Page 105: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 19 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Page 114: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 11 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 115: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 29 APPENDIX 12 Cap Bias Top PCB Layout Art A 11686_AB...
Page 116: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 13 Suppressor PCB Layout Art A 11684_AB...
Page 161: ......