267
Inverter 2A No Input
Power
Inverter section may have no input power. Contactor W1 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
268
Inverter 2B No Input
Power
Inverter section may have no input power. Contactor W2 not closed; Defective contactor or
CB4 tripped; Inverter section input not connected; Defective Inverter.
269
Inverter 3A No Input
Power
Inverter section may have no input power. Contactor W2 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
270
Inverter 3B No Input
Power
Inverter section may have no input power. Contactor W2 not closed; Defective contactor or CB4
tripped; Inverter section input not connected; Defective Inverter.
271 Inverter ID reading
fault
CCM found ID values inconsistant during reading. CCM to an Inverter section ribbon damaged
or disconnected; Inproper ribbon cable routing.
CCM Status Code
Group 3 -- Gas Controller Status & Protocol
Code
Message
Remedy / Comments
301
Not used
Reserved for other models.
302
Reserved
No information available; Contact customer service
303
Gas Supply Pressure
out of range.
Autocut is in SET mode or Plasma gas pressure is too low; Defective gas pressure sensor
(PS1).
304
Gas Control Purging
Normal following power up or returning from Plasma Disable.
305
Not used
Reserved for other models.
306
Not used
Reserved for other future use.
307
Not used
Reserved for other models.
308
Gas Control Type
Mismatch
Wrong CCM, must be Auto-cut type.
309
Not used
Reserved for other models.
310 * DPC fault
Reserved for other models.
311 * DPC valve control fault Reserved for other models.
312 * DMC fault
Reserved for other models.
313 * Gas Controller not
configured.
Reserved for other models.
* Applies to DFC 3000 (Auto Gas) only
Summary of Contents for AUTO-CUT 300 XT
Page 6: ...This Page Intentionally Blank...
Page 13: ...AUTO CUT 300 XT Manual 0 5300 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 52: ...This Page Intentionally Blank...
Page 105: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 19 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Page 114: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 11 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 115: ...AUTO CUT 300 XT Manual 0 5300 APPENDIX A 29 APPENDIX 12 Cap Bias Top PCB Layout Art A 11686_AB...
Page 116: ...AUTO CUT 300 XT APPENDIX Manual 0 5300 APPENDIX 13 Suppressor PCB Layout Art A 11684_AB...
Page 161: ......