Manual No. 0-5056
3-1
INSTALLATION
SECTION 3: INSTALLATION
3.01 Installation Requirements
Electric Supply
The electrical supply network, the gas and water supply system must meet local safety standards. This
conformity shall be checked by qualified personnel.
Input
Power Input
Current
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (AWG)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
208
60
23
105
125
#4
2
230
60
24
98
110
#4
2
400
50
28
58
75
#4
1
400 (CE)
50
28
58
75
#4
1
460
60
26
57
75
#4
1
2
Extra Hard Usage Type G, G-GC, W
Line Voltages with Suggested Circuit Protection and Wire Sizes
1
Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW
Ultra-Cut 200
Power Supply
Suggested Sizes (See Note)
Based on National Electric Code and Canadian Electrical Code
CAUTION
Fuse and wire sizes are for reference only. The installation must conform to national and local codes for the type
and method of wire being used.
Gas Supply
The customer must supply all gases and pressure regulators. Gases must be of high quality. Pressure
regulators must be double-stage and installed as close as possible to the gas console. Contaminated gas
can cause one or more of the following problems:
•
Reduced cutting speed
•
Poor cut quality
•
Poor cutting precision
•
Reduced consumables life.
•
Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.
Cooling System Requirements
Coolant must be added to the system on installation. The amount required varies with torch leads length.
Thermal Dynamics recommends the use of its coolants 7-3580 and 7-3581 (for low temperatures).
Cat. Number and Mixture
Mixture
Protects To
7-3580 'Extra-Cool
TM
'
25 / 75
10° F / -12° C
7-3581 'Ultra-Cool
TM
'
50 / 50
-27° F / -3° C
7-3582 'Extreme Cool
T M
'
Concentrate*
-65° F / -51° C
Coolant Capabilities
* For mixing with D-I Cool
TM
7-3583
Summary of Contents for 200 ULTRA-CUT
Page 4: ...Thispageintentionallyblank ...
Page 8: ......
Page 80: ...Manual No 0 5056 4 16 OPERATION This page intentionally blank ...
Page 110: ...Manual No 0 5056 6 28 Power Supply Parts List Intentionally Blank ...
Page 116: ...TORCH INFORMATION 7 6 Manual 0 5056 This page is blank intentionally ...
Page 129: ...Manual 0 5056 A 13 APPENDIX This page intentionally blank ...