Manual No. 0-5056
2-2
SPECIFICATIONS
2.06 Specifications & Electrical Requirements
Maximum OCV (U
0
)
380 vdc
Maximum Output Current
200 Amps
Maximum Output Voltage
230 vdc
Duty Cycle Rating
100% @ 200A, 180vdc (32 kW),
@ 104F° (40°C) Ambient Temperature
Operating range
14°F to 122°F (-10°C to + 50°C)
Power Factor
0.70 @ 100 ADC Output
Cooling
Forced Air (Class F)
Ultra-Cut® 200 Power Supply Specifications
Input
Power Input
Current
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (AWG)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
208
60
47
130
160
#2
2
230
60
49
125
150
#2
2
400
50
54
77
100
#2
1
400 (CE)
50
54
77
100
#2
1
460
60
59
75
90
#2
1
Ultra-Cut 200 Power Supply Electrical Inputs
2
Extra Hard Usage Type G, G-GC, W
Suggested Sizes (See Note)
Line Voltages with Suggested Circuit Protection and Wire Sizes
1
Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW
Based on National Electric Code and Canadian Electrical Code
2.07 System Component Layout
Refer to section 3.11 for ground connections and ground cables.
Primary power
Work
CNC
Remote
Arc
Starter
Art # A-07233_AB
Torch
Coolant Supply
Coolant Return
Control Cable
Pilot
Return
Coolant Supply
Coolant Return
Plasma Gas
Shield Gas
Work Cable
Fiber
Optic
Cable
Control
Cable
Gas Control
Module
Power
Supply
Torch
Valve
Assembly
Positioning Tube
Plasma Gas
Preflow Gas
Water Shield
Shield
Shield Gas
Negative
Pilot
Return
Control Cable
100’ / 30.5 m Maximum Length
125’ / 38.1 m Maximum Length
175’ / 53.3 m Maximum Length
Shield
H
Q
R
T
S
A
B
C
D
E
P
K
L
O
I
J
G
175’ / 53.3 m Maximum Length
Summary of Contents for 200 ULTRA-CUT
Page 4: ...Thispageintentionallyblank ...
Page 8: ......
Page 80: ...Manual No 0 5056 4 16 OPERATION This page intentionally blank ...
Page 110: ...Manual No 0 5056 6 28 Power Supply Parts List Intentionally Blank ...
Page 116: ...TORCH INFORMATION 7 6 Manual 0 5056 This page is blank intentionally ...
Page 129: ...Manual 0 5056 A 13 APPENDIX This page intentionally blank ...