Manual No. 0-5056
4-11
OPERATION
Status
Code
1-1
System not Enabled or Missing
AC Input Phase
Plasma Enable Off ; External E-Stop Activated or CCM
TB1-1&2 jumper missing; Missing AC Phase; No power
Pilot did not start within 15 seconds.
Preflow pressure too high; Defective Arc Starter
1-3
Lost Pilot
Pilot went out without shutoff signal; Preflow pressure
1-4
Loss of Transfer
Arc transfer (>50 ms.) then arc lost with START still on.
Standoff too high; Current set too low.
1-5
Of the Plate
Function not currently enabled.
1-6
Pilot Timed out w/o Transfer
Must transfer from Pilot to Cutting Arc in 85 ms. (SW8-1
OFF) or 3 sec. (SW8-1 ON). Standoff too high or void in
work under torch; cut current too low for consumables;
Preflow pressure too low.
1-7
Tip Saver
Function not currently enabled.
1-8
Possible Shorted Torch
Detected tip voltage too close to electrode voltage.
Plasma flow/pressure too low; Plasma leak; cut current
too high; shorted torch body; consumable parts worn
out.
2-1
Missing Phase
Blown fuse, Broken or loose connection on power cable
Inverter(s) not configured correctly for input voltage;
Poor power quality (brownouts, dropouts);
Input power capacity / wiring too small causing voltage
drop; broken or loose power cable connections.
2-3
Inverter or Pilot Regulator Over
Temperature
Failed fan; Ambient above 40 deg C. (104 F); Blocked
airflow
2-4
Power Supply not Ready
Defective inverter
2-5
DC Output Low
Output less than 60 VDC; Defective inverter, shorted
output; Shorted pilot regulator (chopper); CCM voltage
sense (J6) wire open or disconnected.
2-6
Primary over current or
imbalance fault
Over current detected in inverter primary circuit, remove
power to reset; defective inverter; voltage surge;
2-7
Unexpected current
Current >20A in work or pilot leads before pilot ignition;
Possible shorted torch; Defective current sensor.
2-8
Unexpected current in pilot
circuit
Current > 5A in pilot circuit; wrong or mismatched
consumables; Pilot lead shorted to negative in torch tube;
Possible shorted torch
2-9
Unexpected current in work
lead
Current > 5A in work lead; Short to chassis in RAS;
Negative lead short to gnd.
2-2
Wrong input voltage
Status Code Key
Message
Cause/Remedy
1-2
Pilot Ignition Failure
Summary of Contents for 200 ULTRA-CUT
Page 4: ...Thispageintentionallyblank ...
Page 8: ......
Page 80: ...Manual No 0 5056 4 16 OPERATION This page intentionally blank ...
Page 110: ...Manual No 0 5056 6 28 Power Supply Parts List Intentionally Blank ...
Page 116: ...TORCH INFORMATION 7 6 Manual 0 5056 This page is blank intentionally ...
Page 129: ...Manual 0 5056 A 13 APPENDIX This page intentionally blank ...