7
A Division of:
3.6 Adjusting the bypass
Use the following procedure to adjust the
bypass:
1.
Open Valve 1 & 2 half way.
2.
Close valve 2 until control shows
NO Or EE3 screen.
3.
Slowly open Valve 2 until pool
Temp shows on screen.
4.
If it shows ‘ON’ or ‘EE3’ on display,
it means the water flow into heat
pump is not enough, then you need
adjust the valves to increase the
water flow through the heat pump.
Must not have Valves open Full.
How to get the optimum water flow:
Please turn on the heat pump under heating function, firstly close the by-pass then open it slowly to start the heat
pump (the heat pump can't start running when the water flow is insufficient).
Continue to adjust the by-pass, at the meantime to check the Inlet water temp. & Outlet water temp, it will be optimum
when the difference is around 2 degrees.
3.7 Electrical connection
Note: Although the heat pump is electrically isolated from the rest of the swimming pool system, this only prevents
the flow of electrical current to, or from the water in the pool. Earthing is still required for protection against short-
circuits inside the unit. Always provide a good earth connection.
Before connecting the unit, verify that the supply voltage matches the operating voltage of the heat pump. It is
recommended to connect the heat pump to a circuit with its own fuse or circuit breaker and to use the appropriate
wiring.
Connect the electrical wires to the terminal block marked ‘ POWER SUPPLY ’.
A second terminal block mark
ed ‘WATER PUMP ’ is located next to the first one. The filter pump (max. 5 A / 240 V) can
be connected to the second terminal block here. This allows the filter pump operation to be controlled by the heat
pump.
3.8 Initial operation
Note: In order to heat the water in the pool (or hot tub), the filter pump must be running to cause the water to
circulate through the heat pump. The heat pump will not start up if the water is not circulating.
After all connections have been made and checked, carry out the following procedure:
1.
Switch on the filter pump. Check for leaks and verify that water is flowing from and to the swimming pool.
Out
Heat
Pump
To
pool
Summary of Contents for 09i
Page 1: ...Swimming Pool Heat Pump User and Service Manual...
Page 2: ......
Page 13: ...11 A Division of Dry contact with a relay system Relay to be supplied by Electrician...
Page 15: ...13 A Division of...
Page 28: ...26 A Division of 8 Exploded Diagram Model Theratherm 09i...
Page 31: ...29 A Division of Model Theratherm 14i...
Page 34: ...32 A Division of Model Theratherm 20i Model Theratherm 25i...
Page 42: ...40 A Division of 4 4 Parameter Query...
Page 44: ...42 A Division of 4 7 Water temperature setting...
Page 46: ......
Page 47: ...A0141PCI 01...