20
A Division of:
7.Troubleshooting
7.1 Error code display on LED wire controller
Error
Code
Malfunction
Reason
Solution
EE 01
High pressure
failure
1.
High pressure switch in bad connection
or failure
2.
Ambient temperature is too high
3.
Water temperature is too high
4.
Water flow is too low
5.
Fan motor speed is abnormal or fan
motor has damaged
1. Check the wiring for high pressure
switch or change a new one
2.Check the water flow or water pump
3.
Check the fan motor
4.
Check and repair the piping system
EE 02
Low pressure
failure
1. Low pressure switch in bad connection or
failure
1.
EEV has
blocked or
pipe
system is jammed
2.
Motor speed is abnormal or motor has
damaged
3.
Gas leakage
1.
Check the wiring for low
pressure switch or change a new one
2.
Check the EEV and piping
system Check the motor
3.
Through the high pressure
gauge to check the pressure value
'ON'
or
EE03
Water flow failure
1.
Water flow switch is in bad connection
2.
Water flow switch is damaged
3.
No/ Insufficient water flow.
1.
Check the wiring for water flow
switch
2.
Change the water flow switch
3.
Check the
water pump or
the waterway system
EE 04
Over heating
protection for
water
temperature (T2)
in heating mode
1.
Low water flow
2.
Water flow switch is stuck and the
water supply is cut off
3.
T2 sensor is abnormal
1.
Check the water way system
2.
Check the water pump or water
flow switch
3.
Check T2 sensor or change another
one
EE 05
Exhaust
temperature (T6)
too
high
protection
1.
Lack of gas
2.
Low water flow
3.
Piping system has been blocked
4.
Exhaust temp. Sensor failure
1.
Check the high pressure gauge, if too
low, fill with some gas
2.
Check the waterway system and
water pump
3.
Check the piping system if there was
any block
4.
Change a new exhaust temp. sensor
EE 06
Controller
malfunction
1.
Wire connection
is
not
good
or damaged signal wire
2.
Controller failure
1.
Check
and
re-connect
the
signal wire
2.
Change a new signal wire
3.
Turn off
electricity
supply and restart machine
4.
Change a new controller
Summary of Contents for 09i
Page 1: ...Swimming Pool Heat Pump User and Service Manual...
Page 2: ......
Page 13: ...11 A Division of Dry contact with a relay system Relay to be supplied by Electrician...
Page 15: ...13 A Division of...
Page 28: ...26 A Division of 8 Exploded Diagram Model Theratherm 09i...
Page 31: ...29 A Division of Model Theratherm 14i...
Page 34: ...32 A Division of Model Theratherm 20i Model Theratherm 25i...
Page 42: ...40 A Division of 4 4 Parameter Query...
Page 44: ...42 A Division of 4 7 Water temperature setting...
Page 46: ......
Page 47: ...A0141PCI 01...