Note: Under Automatic mode, it is useless to set parameter P1 .
Operation logic of Auto Mode:
Set water temperature
(Tset)
Current water in
temperature
(Tset +2
℃
)
Current working
mode
After 3 minutes or
above, it will switch
to
Tset (eg: 28
℃
)
Tset +2
℃
(eg:30
℃
)
Heating mode
Cooling mode
Tset (eg: 28
℃
)
Tset-2
℃
(eg: 26
℃
)
Cooling mode
Heating mode
6.2.3
button
Lock/unlock the display:
Hold
for 5 seconds to lock/unlock the display.
Water temperature setting :
Press
to set the water temperature directly.
Parameter checking :
Press
first, then press
to check the “ User
parameter from d0 to d11”.
Code
Condition
Scope
Remark
d0
IPM mould temperature
0-120
℃
Real testing value
d1
Inlet water temp.
-9
℃~
99
℃
Real testing value
d2
Outlet water temp.
-9
℃~
99
℃
Real testing value
d3
Ambient temp.
-30
℃~
70
℃
Real testing value
d4
Frequency limitation code
0,1,2,4,8,16
Real testing value
d5
Piping temp.
-30
℃~
70
℃
Real testing value
d6
Gas exhaust temperature
0
℃~
C5
℃
(125
℃
)
Real testing value
d7
Step of EEV
0
~
99
N*5
d8
Compressor running frequency
0
~
99Hz
Real testing value
d9
Compressor current
0
~
30A
Real testing value
and
and
or
Summary of Contents for 09i
Page 1: ...Swimming Pool Heat Pump User and Service Manual...
Page 2: ......
Page 13: ...11 A Division of Dry contact with a relay system Relay to be supplied by Electrician...
Page 15: ...13 A Division of...
Page 28: ...26 A Division of 8 Exploded Diagram Model Theratherm 09i...
Page 31: ...29 A Division of Model Theratherm 14i...
Page 34: ...32 A Division of Model Theratherm 20i Model Theratherm 25i...
Page 42: ...40 A Division of 4 4 Parameter Query...
Page 44: ...42 A Division of 4 7 Water temperature setting...
Page 46: ......
Page 47: ...A0141PCI 01...