Page 10

CL-B101D40-TCRTD Manual (d0099)

DIM

Lock

Analog Output

Hold

N/C

SP4

SP3

GND
+5 V

N/C

+ 5 V

SP1

4A

MOV

+ 5 V

SP2

4A

MOV

Display

Driver

Multiplexer

and 

Buffer 

Amplifier

Micro

Processor

100K

100K

0.1

0.1

Input Hi

Input Lo
+5VDC
-5VDC
+24VDC

Ref Hi

Analog Comm

System GND
MUXO
24 V Return

GND

+ 5 V

14 Bit 

Single 

Slope 

A to D

GND

+ 5 V

GND

+ 5 V

 

There are input

modules for almost

any input signal.

 

Input and Output

pins vary for

different modules.

Smart Modules

incorporate their own

A / D converters and

communicate digitally

with the meter.

See section on

I-Series Input Modules

for connection details.

INPUT MODULES

1

2

5

4

3

6

PROCESSOR BOARD

27

26

25

24

23

22

29

28

AC Neutral,

– DC

AC Line,

+ DC

14

8
9

10
11

15

Volts

mA

HEADER

17

16

Chassis Ground Tab for Optional Metal Case

Socket for Input Signal

Conditioning Module

Common

Mode Line

Choke

Bridge

Rectifier

PTC for HI Voltage

Fuse for LO Voltage

Isolated Feed Back

Isolated 

Switching

Power 
Supply

Controller

-5 VDC

+18 VDC ISO

+5 VDC

+5 VDC

GND

+24 VDC

LC Filter

+

1
2
3
4
5
6
7
8
9

10

RELAY MODULES

NO3

COM 1 & 3

NO1

NC1

NO4

COM 2 & 4

NO2

NC2

MOV's

9A

4A

+ 5 V

SP3

+ 5 V

SP1

MOV's

9A

4A

+ 5 V

SP4

+ 5 V

SP2

- O/P

+ O/P

ANALOG 

OUTPUT

+18V

ISO

+5VDC

Isolated

Analog

Output

Dual 

or Single

ANALOG OUTPUT

MAIN BOARD

24V ISO RTN

GND

Output pins vary for different relay output modules.

August 13, 2002

CARRIER BOARD

1  3  5  7  

2 4 6 8

9  

10

LOCK

No Function

COMMON

DIM

DISPLAY BOARD

Relay Activation LEDs

Bargraph 

Segments

Digital Display

Programming Buttons

Functional Diagram

Pinout Diagram

The Rear View of the Meter diagram shows the meter with the 

relay configuration: dual 9 Amp Form C and dual 4 Amp Form 

A relays� An analog output module is also shown as installed�
The CL-B101D40-TCRTD uses plug-in type screw terminal con-

nectors for all input and output connections� The power supply 

connections (pins 14 and 15) have a unique plug and socket out-

line to prevent cross connection� The main board and input signal 

conditioner use right-angled connectors as standard� The output 

module uses straight-thru connectors as standard�

WARNING

AC and DC input signals and power supply 

voltages can be hazardous. Do Not connect live wires to 

screw terminal plugs, and do not insert, remove or handle 

screw terminal plugs with live wires connected.

Standard plug-in screw terminal connectors provided by Texmate:

Connector Pinouts

Connector Pinouts

Input Signal – Pins 1 to 6

 

Pins 1 to 6 are reserved for the input signal conditioner�  

See the data sheet for the selected input signal conditioner� 

Pins 8 to 11 – Rear Panel Function Pins 

 

Pins 8 to 11

 provide functions that can be implemented 

with an external switch. Their pin definitions are:

 

 

Pin 11  DIM.

 By connecting the display dim (DIM) pin to  

 

the COMMON pin, the display brightness setting  

             is halved�

 

Pin 10  COMMON.

 To activate the LOCK or DIM  

 

functions from the rear of the meter, the  

 

respective pins have to be connected to the  

 

COMMON pin� This pin is connected to the  

 

internal power supply ground�

 

Pin 9  No function

 

Pin 8  LOCK.  

 By connecting the LOCK pin to the  

 

COMMON pin, the meter's programmed  

 

parameters can be viewed but not changed�

17 16

14 15

8

9

10 11

See Leopard Family Input 

Signal Conditioning Modules

1

2

3

4

5

6

21 20 19

Relay Outputs

Reserved for RS-485

LOCK

COMMON

No Function

DIM

ANALOG  OUTPUT – 

AC

Neutral

– DC

AC

Line

+ DC

ANALOG  

29 28 27 26 25 24 23 22

Auto-sensing AC/DC power supply� For voltages between 

85-265 V AC / 95-300 V DC (PS1) or 18-48 V AC / 10-72 V DC (PS2).

Summary of Contents for CL-B101D40-TCRTD

Page 1: ...or below Lo each setpoint Digital display blanking Decimal point setting Four level brightness control LEOPARD FAMILY Input Specs Depends on Input signal conditioner A D Converter 14 bit single slope...

Page 2: ...direction indicated by the arrow When an alternative dotted line is shown this indicates that an alternative logic branch will be followed when a particular option is present When two buttons are sho...

Page 3: ...999 seconds Pump PUM Hysteresis hYSt Hysteresis hYSt Hysteresis hYSt Setpoint 3 SP3 Setpoint 4 SP4 Operational Display MAIN MENU BRIGHTNESS AND SETPOINT VIEW MODE Bargraph Center Point Display Selecti...

Page 4: ...E STEP A Calibration Mode STEP B Calibration Mode To Digital Span Selection for Bargraph Display Page 5 cAL out iP branch will only appear if the analog output option is installed otherwise cAL on goe...

Page 5: ...between Cto and oFF the software is detecting that the optional analog output hardware is NOT installed Digital Span Selection For Bargraph Display Bargraph does not light up for Input Signals up to...

Page 6: ...igh and AnLo analog low can be reversed to provide a 20 to 4mA output The digital span selected can be as small as two counts when using the analog output to function as a Control or Alarm Driver Smal...

Page 7: ...nd 18 see Rear Panel Pinouts on page 10 Using the and buttons adjust the analog output to the desired low value as measured on the multimeter cLo may be adjusted to any value from 0 3 mA to 18 mA mA o...

Page 8: ...Press the P button Display toggles between PUM and on or oFF STEP F Select Pump PUM on or oFF 1 Using the and buttons select the Pump to be ON or OFF When PUM is selected ON and SP2 is set at a value...

Page 9: ...Bargraph Color when the bar is ABOVE SP2 Setpoint 1 Using the and buttons select the desired bargraph color grn oran or red 2 Press the P button Display toggles between CSP3 and the previous color se...

Page 10: ...p Form A relays An analog output module is also shown as installed The CL B101D40 TCRTD uses plug in type screw terminal con nectors for all input and output connections The power supply connections p...

Page 11: ...5A SP4 SP3 SP2 SP1 SP1 SP2 SP3 SP4 Relay Modules with 4 Isolated 5A Form A Relays Output Carrier Board Output Carrier Board Relay Module Relay Module Input Signal Conditioner Analog Output Module Mai...

Page 12: ...the back panel back into the case Apply power to the meter 4 Enter the program mode and select the type of thermocouple J K R T the resolution 0 1 or 1 and the display units C or F See Page 4 of the d...

Page 13: ...10 72VDC Input Modules Partial List See www texmate com IT10 Thermocouple J K R T Selectable C F 1 0 1 IT11 RTD 100 Pt Selectable 3 4 wire C F 1 0 1 385 392 IT15 RTD 1000 Pt Selectable 3 4 wire C F 1...

Reviews: