CL-B101D40-TCRTD Manual (d0099)
DIM
Lock
Analog Output
Hold
N/C
SP4
SP3
GND
+5 V
N/C
+ 5 V
SP1
4A
MOV
+ 5 V
SP2
4A
MOV
Display
Driver
Multiplexer
and
Buffer
Amplifier
Micro
Processor
100K
100K
0.1
0.1
Input Hi
Input Lo
+5VDC
-5VDC
+24VDC
Ref Hi
Analog Comm
System GND
MUXO
24 V Return
GND
+ 5 V
14 Bit
Single
Slope
A to D
GND
+ 5 V
GND
+ 5 V
There are input
modules for almost
any input signal.
Input and Output
pins vary for
different modules.
Smart Modules
incorporate their own
A / D converters and
communicate digitally
with the meter.
See section on
I-Series Input Modules
for connection details.
INPUT MODULES
1
2
5
4
3
6
PROCESSOR BOARD
27
26
25
24
23
22
29
28
AC Neutral,
– DC
AC Line,
+ DC
14
8
9
10
11
15
Volts
mA
HEADER
17
16
Chassis Ground Tab for Optional Metal Case
Socket for Input Signal
Conditioning Module
Common
Mode Line
Choke
Bridge
Rectifier
PTC for HI Voltage
Fuse for LO Voltage
Isolated Feed Back
Isolated
Switching
Power
Supply
Controller
-5 VDC
+18 VDC ISO
–
+5 VDC
+5 VDC
GND
+24 VDC
LC Filter
+
1
2
3
4
5
6
7
8
9
10
RELAY MODULES
NO3
COM 1 & 3
NO1
NC1
NO4
COM 2 & 4
NO2
NC2
MOV's
9A
4A
+ 5 V
SP3
+ 5 V
SP1
MOV's
9A
4A
+ 5 V
SP4
+ 5 V
SP2
- O/P
+ O/P
ANALOG
OUTPUT
+18V
ISO
+5VDC
Isolated
Analog
Output
Dual
or Single
ANALOG OUTPUT
MAIN BOARD
24V ISO RTN
GND
Output pins vary for different relay output modules.
August 13, 2002
CARRIER BOARD
1 3 5 7
2 4 6 8
9
10
LOCK
No Function
COMMON
DIM
DISPLAY BOARD
Relay Activation LEDs
Bargraph
Segments
Digital Display
Programming Buttons
Functional Diagram
Pinout Diagram
The Rear View of the Meter diagram shows the meter with the
relay configuration: dual 9 Amp Form C and dual 4 Amp Form
A relays� An analog output module is also shown as installed�
The CL-B101D40-TCRTD uses plug-in type screw terminal con-
nectors for all input and output connections� The power supply
connections (pins 14 and 15) have a unique plug and socket out-
line to prevent cross connection� The main board and input signal
conditioner use right-angled connectors as standard� The output
module uses straight-thru connectors as standard�
WARNING
:
AC and DC input signals and power supply
voltages can be hazardous. Do Not connect live wires to
screw terminal plugs, and do not insert, remove or handle
screw terminal plugs with live wires connected.
Standard plug-in screw terminal connectors provided by Texmate:
Connector Pinouts
Connector Pinouts
Input Signal – Pins 1 to 6
Pins 1 to 6 are reserved for the input signal conditioner�
See the data sheet for the selected input signal conditioner�
Pins 8 to 11 – Rear Panel Function Pins
Pins 8 to 11
provide functions that can be implemented
with an external switch. Their pin definitions are:
Pin 11 DIM.
By connecting the display dim (DIM) pin to
the COMMON pin, the display brightness setting
is halved�
Pin 10 COMMON.
To activate the LOCK or DIM
functions from the rear of the meter, the
respective pins have to be connected to the
COMMON pin� This pin is connected to the
internal power supply ground�
Pin 9 No function
Pin 8 LOCK.
By connecting the LOCK pin to the
COMMON pin, the meter's programmed
parameters can be viewed but not changed�
17 16
14 15
8
9
10 11
See Leopard Family Input
Signal Conditioning Modules
1
2
3
4
5
6
21 20 19
Relay Outputs
Reserved for RS-485
LOCK
COMMON
No Function
DIM
ANALOG OUTPUT –
AC
Neutral
– DC
AC
Line
+ DC
ANALOG
29 28 27 26 25 24 23 22
Auto-sensing AC/DC power supply� For voltages between
85-265 V AC / 95-300 V DC (PS1) or 18-48 V AC / 10-72 V DC (PS2).