background image

CL-B101D40-TCRTD Manual (d0099)

Page 11

29

28 27

25

26

24 23 22

DL Series

Options

4A

4A

Order Code

OR11

OR12

OR23

OR14

-

-

-

-

-

-

-

4A

4A

4A

4A

10A

-

-

OR15

OR16

SP2

SP4

SP1

SP3

9A

9A

9A

9A

9A

9A

9A

9A

SP3

SP1

SP4

SP2

Relay Modules with 2 Non-Isolated 4A Form A Relays,

and 2 Non-Isolated 9A Form C Relays

29

28 27

25

26

24 23 22

DL Series

Options

Order Code

OR51
OR52

OR53

OR54

-
-
-

-

-

-

210mA
210mA

210mA

210mA

210mA

210mA

210mA

210mA

210mA

210mA

SP4

SP3

SP2

SP1

SP4

SP3

SP2

SP1

Relay Modules with 4 Independent 300V

(210mA DC only)

29

28

27

25

26

24

23

22

DL Series

Options

Order Code

OR31

OR32

OR33

OR34

-

-

-

-

-

-

5A

5A

5A

5A

5A

5A

5A

5A

5A

5A

SP4

SP3

SP2

SP1

SP1

SP2

SP3

SP4

Relay Modules with 4 Isolated 5A Form A Relays

Output

Carrier

Board

Output

Carrier

Board

Relay 

Module

Relay 

Module

Input Signal 

Conditioner

Analog Output 

Module

Main 

Board

Display

Board

Component Layout

Component Layout

Connector Pinouts continued

AC/DC Power Input- Pins 14 and 15 

Auto-sensing AC/DC power supply� For voltages between 

85-265 V AC/95-300 V DC (PS1) or 18-48 V AC/10-72 V DC (PS2).

 

Pin 14  AC/DC Neutral.

 Neutral power supply line� 

Pin 15  AC/DC line.

 Live power supply line�

Optional Carrier Board Output Pins

Analog Output- Pins 16 and 17  

Pins 16 and 17 are the analog output pins on the optional 

output module� Their pin definitions are: 

Pin 16

    Positive (+) analog output� 

Pin 17

    Negative (–) analog output�

RS-485 Output- Pins 19, 21 and 21

Pins 22 to 29 – Output Module Pins

Summary of Contents for CL-B101D40-TCRTD

Page 1: ...or below Lo each setpoint Digital display blanking Decimal point setting Four level brightness control LEOPARD FAMILY Input Specs Depends on Input signal conditioner A D Converter 14 bit single slope...

Page 2: ...direction indicated by the arrow When an alternative dotted line is shown this indicates that an alternative logic branch will be followed when a particular option is present When two buttons are sho...

Page 3: ...999 seconds Pump PUM Hysteresis hYSt Hysteresis hYSt Hysteresis hYSt Setpoint 3 SP3 Setpoint 4 SP4 Operational Display MAIN MENU BRIGHTNESS AND SETPOINT VIEW MODE Bargraph Center Point Display Selecti...

Page 4: ...E STEP A Calibration Mode STEP B Calibration Mode To Digital Span Selection for Bargraph Display Page 5 cAL out iP branch will only appear if the analog output option is installed otherwise cAL on goe...

Page 5: ...between Cto and oFF the software is detecting that the optional analog output hardware is NOT installed Digital Span Selection For Bargraph Display Bargraph does not light up for Input Signals up to...

Page 6: ...igh and AnLo analog low can be reversed to provide a 20 to 4mA output The digital span selected can be as small as two counts when using the analog output to function as a Control or Alarm Driver Smal...

Page 7: ...nd 18 see Rear Panel Pinouts on page 10 Using the and buttons adjust the analog output to the desired low value as measured on the multimeter cLo may be adjusted to any value from 0 3 mA to 18 mA mA o...

Page 8: ...Press the P button Display toggles between PUM and on or oFF STEP F Select Pump PUM on or oFF 1 Using the and buttons select the Pump to be ON or OFF When PUM is selected ON and SP2 is set at a value...

Page 9: ...Bargraph Color when the bar is ABOVE SP2 Setpoint 1 Using the and buttons select the desired bargraph color grn oran or red 2 Press the P button Display toggles between CSP3 and the previous color se...

Page 10: ...p Form A relays An analog output module is also shown as installed The CL B101D40 TCRTD uses plug in type screw terminal con nectors for all input and output connections The power supply connections p...

Page 11: ...5A SP4 SP3 SP2 SP1 SP1 SP2 SP3 SP4 Relay Modules with 4 Isolated 5A Form A Relays Output Carrier Board Output Carrier Board Relay Module Relay Module Input Signal Conditioner Analog Output Module Mai...

Page 12: ...the back panel back into the case Apply power to the meter 4 Enter the program mode and select the type of thermocouple J K R T the resolution 0 1 or 1 and the display units C or F See Page 4 of the d...

Page 13: ...10 72VDC Input Modules Partial List See www texmate com IT10 Thermocouple J K R T Selectable C F 1 0 1 IT11 RTD 100 Pt Selectable 3 4 wire C F 1 0 1 385 392 IT15 RTD 1000 Pt Selectable 3 4 wire C F 1...